Use of a portable forced air system to convert existing hospital space into a mass casualty isolation area

被引:23
作者
Rosenbaum, RA
Benyo, JS
O'Connor, RE
Passarello, BA
Williams, DR
Humphrey, BD
Ross, RW
Berry, JM
Krebs, JG
机构
[1] Dept Emergency Med, Christiana Care Hlth Syst, Newark, DE 19718 USA
[2] Dept Emergency Med, Dept Publ Safety, Newark, DE 19718 USA
[3] Dept Emergency Med, Dept Occupat Hlth & Facil Management, Newark, DE 19718 USA
[4] Publ Hlth Preparedness Sect, Dover, DE USA
[5] Div Publ Hlth, Dover, DE USA
关键词
D O I
10.1016/j.annemergmed.2004.03.012
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: Patients with communicable diseases may require respiratory isolation to reduce the chance of transmission to health care workers and the public. This project was conducted to determine whether negative-pressure isolation for multiple patients can be achieved quickly and effectively using general hospital space not previously dedicated to respiratory isolation. Methods: The physical therapy gymnasium was the area designated to test the ability to create a negative-pressure isolation environment in a large space. The conversion was planned in advance of an unscheduled drill to convert the space. Four high efficiency particulate air (HEPA) filtered forced air machines were used to generate negative pressure. The units were vented to the outside air by a 25-foot length of 10-inch-diameter reusable duct. We evaluated the time needed for equipment setup and room conversion and noted any subjective difficulty with either setup or operation of the equipment. We measured the ability of the equipment to generate a negative air pressure relative to adjacent areas and determined the noise levels created during the use of different combinations of machines at various power settings. Results: After drill activation and the request for equipment setup, I hour was required to convert the physical therapy gymnasium into an operational negative-pressure environment. The room pressure readings "high" power ranged from -1.5 to -13 Pa (-0.006 to -0.052 inches of water), and noise levels ranged from 70 to 76 dB. Calculated air changes per hour using 1, 2, 3, or 4 units running simultaneously at "high" power were 4.1, 8.2, 12.3, and 16.4, respectively. Using 4 units at once running at "low" power setting yielded 8.2 air changes per hour and generated a room pressure reading of -8.0 Pa, or -0.032 inches of water. Conclusion: Portable H EPA filtered forced air units are an effective means of creating large patient care areas with the negative-pressure environment required for respiratory isolation. This design results in a significantly lower-cost alternative compared with construction of individual rooms or units with similar capability and can be retrofitted to existing space. This type of unit would allow treatment of many more patients than current hospital capability would permit and would be an important asset in meeting the needs created by bioterrorism or a naturally occurring epidemic.
引用
收藏
页码:628 / 634
页数:7
相关论文
共 10 条
[1]  
*AM I ARCH, 2001, GUID DES CONSTR HOSP
[2]  
BURROUGHS HEB, 1997, GUIDE MANAGING INDOO, P3
[3]  
*CDCP, 2003, MMWR-MORBID MORTAL W, V52, P433
[4]   SARS outbreaks in Ontario, Hong Kong and Singapore: the role of diagnosis and isolation as a control mechanism [J].
Chowell, G ;
Fenimore, PW ;
Castillo-Garsow, MA ;
Castillo-Chavez, C .
JOURNAL OF THEORETICAL BIOLOGY, 2003, 224 (01) :1-8
[5]  
FRASER VJ, 1993, INFECT CONT HOSP EP, V14, P623
[6]   THE CDC HOSPITAL INFECTION-CONTROL PRACTICES ADVISORY-COMMITTEE [J].
GARNER, JS .
AMERICAN JOURNAL OF INFECTION CONTROL, 1993, 21 (03) :160-162
[7]  
McPherson D C, 1988, J Healthc Mater Manage, V6, ppassim
[8]   Identification of factors that disrupt negative air pressurization of respiratory isolation rooms [J].
Pavelchak, N ;
DePersis, RP ;
London, M ;
Stricof, R ;
Oxtoby, M ;
DiFerdinando, G ;
Marshall, E .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2000, 21 (03) :191-195
[9]  
Sehulster L.M., 2004, GUIDELINES ENV INFEC
[10]  
1997, ECRI, V26, P367