Biological fixation of hydroxyapatite-coated versus grit-blasted titanium hip stems: a canine study

被引:24
作者
Eckardt, A
Aberman, HM
Cantwell, HD
Heine, J
机构
[1] Univ Mainz, Sch Med, Dept Orthopaed, D-55101 Mainz, Germany
[2] Howmedica, Res & Dev Ctr, Rutherford, NJ USA
[3] Mississippi State Univ, Coll Vet Med, Mississippi State, MS 39762 USA
关键词
osseointegration; cementless hip stem; hydroxyapatite; endoprosthesis; titanium surface; BONE INGROWTH; IMPLANTS; REPLACEMENT; ARTHROPLASTY; PROSTHESIS; STORAGE; MODEL;
D O I
10.1007/s00402-002-0451-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: The purpose of the study was to evaluate the influence of a proximal hydroxyapatite (HA) coating in comparison with a grit-blasted titanium surface of an anatomic hip stem in an animal model over a maximum duration of 2 years. Methods: Thirty adult dogs underwent implantation of either a proximally HA-coated or a grit-blasted anatomic titanium stem. The animals were clinically evaluated for their walking ability, and serial radiographs were taken. The femora were assessed histomorphologically at set time points from 6 weeks to 2 years postoperatively. Undecalcified thin section specimens through the proximal and distal portion of the coating or grit blasting were prepared. The percentage of implant surface with direct bone contact without connective tissue involvement was determined. Results: Radiographically, animals with uncoated prostheses showed characteristic signs of loosening more frequently. Histomorphometrically, an average of 65% of the surface of HA-coated implants had bone contact, but only 14.7% of the surface of grit-blasted prostheses (p=0.0001). There was no relationship between bone contact and the duration of implantation of the prosthesis, either for the coated or for the uncoated prostheses. HA coating enhances osseointegration of an anatomic hip stem. Conclusion: Anatomic stems with rounded design require a surface coating or surface structure, since the mere grit-blasting of the titanium surface does not ensure osseointegration in this animal model.
引用
收藏
页码:28 / 35
页数:8
相关论文
共 56 条
[1]
A COMPARISON OF HIP-JOINT FORCES IN SHEEP, DOG AND MAN [J].
BERGMANN, G ;
SIRAKY, J ;
ROHLMANN, A ;
KOELBEL, R .
JOURNAL OF BIOMECHANICS, 1984, 17 (12) :907-&
[2]
COMPARISON OF HUMAN AND CANINE EXTERNAL FEMORAL MORPHOLOGIES IN THE CONTEXT OF TOTAL HIP-REPLACEMENT [J].
BLOEBAUM, RD ;
OTA, DT ;
SKEDROS, JG ;
MANTAS, JP .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (09) :1149-1159
[3]
THE EFFECT OF PROXIMALLY AND FULLY POROUS-COATED CANINE HIP STEM DESIGN ON BONE MODELING [J].
BOBYN, JD ;
PILLIAR, RM ;
BINNINGTON, AG ;
SZIVEK, JA .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1987, 5 (03) :393-408
[4]
BOBYN JD, 1990, T ORTHOP RES SOC, V15, P202
[5]
CHEN PQ, 1983, CLIN ORTHOP RELAT R, P24
[6]
COCHRAN GVB, 1982, PRIMER ORTHOPAEDIC B, P71
[7]
HYDROXYLAPATITE COATING OF POROUS IMPLANTS IMPROVES BONE INGROWTH AND INTERFACE ATTACHMENT STRENGTH [J].
COOK, SD ;
THOMAS, KA ;
DALTON, JE ;
VOLKMAN, TK ;
WHITECLOUD, TS ;
KAY, JF .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (08) :989-1001
[8]
RADIOGRAPHIC ASSESSMENT OF A CANINE UNCEMENTED POROUS-COATED ANATOMIC TOTAL HIP-PROSTHESIS [J].
DEYOUNG, DJ ;
SCHILLER, RA ;
DEYOUNG, BA .
VETERINARY SURGERY, 1993, 22 (06) :473-481
[9]
RADIOGRAPHIC CRITERIA FOR EVALUATION OF UNCEMENTED TOTAL HIP-REPLACEMENT IN DOGS [J].
DEYOUNG, DJ ;
SCHILLER, RA .
VETERINARY SURGERY, 1992, 21 (02) :88-98
[10]
IMPLANTATION OF AN UNCEMENTED TOTAL HIP-PROSTHESIS - TECHNIQUE AND INITIAL RESULTS OF 100 ARTHROPLASTIES [J].
DEYOUNG, DJ ;
DEYOUNG, BA ;
ABERMAN, HA ;
KENNA, RV ;
HUNGERFORD, DS .
VETERINARY SURGERY, 1992, 21 (03) :168-177