The reproducibility of multi-joint isokinetic and isometric assessments in a healthy and patient population

被引:41
作者
Callaghan, MJ [1 ]
McCarthy, CJ [1 ]
Al-Omar, A [1 ]
Oldham, JA [1 ]
机构
[1] Manchester Royal Infirm, Ctr Rehabil Sci, Manchester M13 9WL, Lancs, England
关键词
reproducibility; knee joint; isokinetic; isometric; multi-joint testing; Biodex; patellofemoral pain syndrome;
D O I
10.1016/S0268-0033(00)00032-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Design. Test re-test reliability design. Objective. To determine a reproducible protocol for lower limb simultaneous multi-joint assessments on a healthy group of subjects and a patient group with patellofemoral pain syndrome. Background. Although single joint assessment with isokinetic dynamometers has been utilised for many years in knee rehabilitation, simultaneous multi-joint assessment has not attracted comparable attention. Methods. Twenty healthy volunteers mean age 30.6 years and 16 patients with patellofemoral pain syndrome mean age 29.6 years performed isometric maximum voluntary contractions and concentric isokinetic contractions of the lower limb. Data were collected on three separate days for resultant extension/flexion peak torque, average power and total work which were analysed using intraclass correlation coefficients with a 95% level of confidence. Results. In healthy subjects, intraclass correlation coefficients estimates were greater than or equal to 0.75 for isokinetic peak torque and > 0.83 for average power and total work. The intraclass correlation coefficients estimate for isometric peak torque extension was 0.82. In the patient group, intraclass correlation coefficients estimates were > 0.82 for isokinetic peak torque and greater than or equal to 0.75 for average power and total work. The intraclass correlation coefficients estimate for isometric peak torque extension was 0.89. Discarding the first session's data for both groups improved the intraclass correlation coefficients estimates for virtually all assessments. Conclusions. This study has demonstrated high reproducibility of lower limb multi-joint testing for peak torque, average power, and total work on healthy subjects and then has employed the protocol to demonstrate similarly high reliability on a patient group. It has also highlighted the need for a practice session before the data can be said to be reliable. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:678 / 683
页数:6
相关论文
共 25 条
[1]  
[Anonymous], ISOKINET EXERC SCI
[2]  
BOHANNON R W, 1989, Journal of Orthopaedic and Sports Physical Therapy, V11, P155
[3]   OPEN VERSUS CLOSED CHAIN KINETIC EXERCISES AFTER ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION - A PROSPECTIVE RANDOMIZED STUDY [J].
BYNUM, EB ;
BARRACK, RL ;
ALEXANDER, AH .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1995, 23 (04) :401-406
[4]  
DOXEY G E, 1987, Journal of Orthopaedic and Sports Physical Therapy, V9, P211
[5]   An isokinetic study of combined activity of the hip and knee extensors [J].
Dvir, Z .
CLINICAL BIOMECHANICS, 1996, 11 (03) :135-138
[6]  
Dvir Z, 1995, ISOKINETICS MUSCLE T
[7]   Biomechanics of the knee during closed kinetic chain and open kinetic chain exercises [J].
Escamilla, RF ;
Fleisig, GS ;
Zheng, NG ;
Barrentine, SW ;
Wilk, KE ;
Andrews, JR .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1998, 30 (04) :556-569
[8]  
FEIRING D C, 1990, Journal of Orthopaedic and Sports Physical Therapy, V11, P298
[9]   Intratester and intertester reproducibility of the lumbar motion monitor as a measure of range, velocity and acceleration of the thoracolumbar spine [J].
Gill, KP ;
Callaghan, MJ .
CLINICAL BIOMECHANICS, 1996, 11 (07) :418-421
[10]  
HARDING B, 1988, Journal of Orthopaedic and Sports Physical Therapy, V10, P218