Motion pattern and posture: Correctly assessed by calibrated accelerometers

被引:114
作者
Foerster, F [1 ]
Fahrenberg, J [1 ]
机构
[1] Univ Freiburg, Forsch Grp Psychophysiol, D-79085 Freiburg, Germany
来源
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS | 2000年 / 32卷 / 03期
关键词
D O I
10.3758/BF03200815
中图分类号
B841 [心理学研究方法];
学科分类号
040201 ;
摘要
Basic motion patterns and posture can be distinguished by multichannel accelerometry, as recently shown. A refinement of this method appeared to be desirable to further increase its effectiveness, especially to distinguish walking and climbing stairs, and body rotation during sleep. Recordings were made of 31 subjects, according to a standard protocol comprising 13 motions and postures. This recording was repeated three times with appropriate permutation. Five uni-axial sensors and three sites of placement (sternum with three axes, right and left thigh) were selected. A hierarchical classification strategy used a standard protocol (i.e., individual reference patterns) to distinguish subtypes of moving behaviors and posture. The analysis method of the actometer signals reliably detected 13 different postural and activity conditions (only 3.2 % misclassifications). A minimum set of sensors can be found for a given application; for example, a two-sensor configuration would clearly suffice to differentiate between four basic classes (sitting, standing, lying, moving) in ambulatory monitoring.
引用
收藏
页码:450 / 457
页数:8
相关论文
共 29 条
  • [1] [Anonymous], DYNAMIC ANAL USING B
  • [2] [Anonymous], AMBULATORY ASSESSMEN
  • [3] [Anonymous], 1996, Ambulatory assessment. Computer-assisted psychological and physiological methods in monitoring and field studies
  • [4] [Anonymous], 1991, AMBULATORY MONITORIN
  • [5] Daily physical activity assessment: Comparison between movement registration and doubly labeled water
    Bouten, CVC
    VerboeketVandeVenne, WPHG
    Westerterp, KR
    Verduin, M
    Janssen, JD
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (02) : 1019 - 1026
  • [6] Ambulatory monitoring of children's activity
    Busser, HJ
    Ott, J
    vanLummel, RC
    Uiterwaal, M
    Blank, R
    [J]. MEDICAL ENGINEERING & PHYSICS, 1997, 19 (05) : 440 - 445
  • [7] BUSSER HJ, 1994, DYNAMIC ANAL USING B, P107
  • [8] BUSSMANN H, 1998, AMBULATORY MONITORIN
  • [9] Quantification of physical activities by means of ambulatory accelerometry: A validation study
    Bussmann, JBJ
    Tulen, JHM
    van Herel, ECG
    Stam, HJ
    [J]. PSYCHOPHYSIOLOGY, 1998, 35 (05) : 488 - 496
  • [10] BUSSMANN JBJ, 1994, DYNAMIC ANAL USING B, P13