Development of system suitability tests for ion-interaction chromatography of colorants on reversed-phase packing materials

被引:13
作者
Angelino, S
Fell, AF
Gennaro, MC
机构
[1] Univ Turin, Dipartimento Chim Analit, I-10125 Turin, Italy
[2] Univ Bradford, Pharmaceut Anal Res Unit, Bradford BD7 1DP, W Yorkshire, England
关键词
ion-interaction chromatography; system suitability tests; mobile phase composition; dyes;
D O I
10.1016/S0021-9673(97)01034-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ion-interaction reagent (IIR) chromatography has been established as a highly selective and sensitive method for studies on ionic solutes in environmental and food analysis. This technique makes use of a mobile phase containing an ion-interaction reagent (alkylammonium phosphate) which, flowing in isocratic conditions, induces a modification of the stationary phase surface. The formation of an electrical double-layer adsorbed onto the original RP packing material permits the separation of anionic and/or cationic species. As an essential requirement for transferring of IIR methods, it is necessary to devise suitable conditions for validation of the methods. The present work describes the development of system suitability tests (SSTs) based on a group of red dyes as a model system, where the influence of a number of parameters has been examined, including: organic modifier percentage, mobile phase pH, alkylamine chain length, IIR concentration, column temperature, flow-rate, sample composition. Some factors affecting sample stability have also been explored. To extend the results, two yellow dyes were added to the mixture, to provide a group of peaks characterized by critical resolution. Standardized conditions are proposed to assess the suitability of a new column packing material for adequate resolution of the proposed system. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:65 / 74
页数:10
相关论文
共 7 条
[1]   TEMPERATURE-DEPENDENCE OF RETENTION IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY .1. STATIONARY-PHASE CONSIDERATIONS [J].
COLE, LA ;
DORSEY, JG .
ANALYTICAL CHEMISTRY, 1992, 64 (13) :1317-1323
[2]   Separation of a mixture of hydrophilic and hydrophobic herbicides by ion-interaction reversed-phase HPLC [J].
Gennaro, MC ;
Giacosa, D ;
Abrigo, C ;
Simonetti, S .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1996, 34 (07) :334-340
[3]   RETENTION OF ANIONS AS A FUNCTION OF MOBILE-PHASE PH IN ION-INTERACTION RP-HPLC [J].
GENNARO, MC ;
ABRIGO, C ;
MARENGO, E .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (06) :1231-1244
[4]  
GENNARO MC, 1995, ADV CHROMATOGR, V35, P343
[5]  
LOPESMARQUES RM, 1992, J CHROMATOGR, V592, P157
[6]   REQUIREMENTS AND TESTS FOR HPLC APPARATUS AND METHODS IN PHARMACEUTICAL QUALITY-CONTROL [J].
MALDENER, G .
CHROMATOGRAPHIA, 1989, 28 (1-2) :85-88
[7]  
YAMAMOTO FM, 1989, J CHROMATOGR SCI, V27