Physical dosimetry techniques used for radiological accident reconstitution

被引:1
作者
Bottollier-Depois, JF [1 ]
Chau, Q [1 ]
Gaillard-Lecanu, E [1 ]
Medioni, R [1 ]
Roux, A [1 ]
机构
[1] Inst Protect & Surete Nucl, Dept Protect Sante Homme & Dosimetrie, Serv Dosimetrie, IPSN, F-92265 Fontenay Aux Roses, France
关键词
radiological accident; dosimetric reconstitution;
D O I
10.1051/jcp:1998179
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
When a radiological accident occurred, the distribution of the dose received in the organism must be assessed within a short time. This information, which completes the clinical and biological investigations, is useful for the medical team. In this way, the physical dosimetry makes use of experimental and numerical reconstitution techniques which are generally complementary. The numerical technique consists in simulating the particles transport with a calculation code based on the Monte-Carlo method in a geometry which represents the injured person and the environment. The experimental reconstitution is performed with tissue equivalent phantoms and special dosemeters.
引用
收藏
页码:685 / 690
页数:6
相关论文
共 3 条
[1]  
BOTTOLLIERDEPOI.JF, 1997, C SFRP AV 18 20 JUIN
[2]  
*ORNL, 1987, MORSE GEN PURP MONT
[3]  
*US ARM BALL RES L, 1991, MGED US MAN, V4, pCH11