Optimization and life-cycle cost of health clinic PV system for a rural area in southern Iraq using HOMER software

被引:150
作者
Al-Karaghouli, Ali [1 ]
Kazmerski, L. L. [1 ]
机构
[1] Natl Renewable Energy Lab, Golden, CO 80401 USA
关键词
Photovoltaics (PV); Stand-alone system; Rural electrification; Rural area in Iraq; System; Design;
D O I
10.1016/j.solener.2010.01.024
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper addresses the need for electricity of rural areas in southern Iraq and proposes a photovoltaic (PV) solar system to power a health clinic in that region. The total daily health clinic load is 31.6 kWh and detailed loads are listed. The National Renewable Energy Laboratory (NREL) optimization computer model for distributed power, "HOMER," is used to estimate the system size and its life-cycle cost. The analysis shows that the optimal system's initial cost, net present cost, and electricity cost is US$ 50,700, US$ 60,375, and US$ 0.238/kW h, respectively. These values for the PV system are compared with those of a generator alone used to supply the load. We found that the initial cost, net present cost of the generator system, and electricity cost are US$ 4500, US$ 352,303, and US$ 1.332/kW h, respectively. We conclude that using the PV system is justified on humanitarian, technical, and economic grounds. (C) 2010 Published by Elsevier Ltd.
引用
收藏
页码:710 / 714
页数:5
相关论文
共 3 条
[1]  
*SOL LLC, 2008, SOL EN EL PRIC REP
[2]  
Solar Energy International, 2004, PHOT DES INST MAN
[3]  
*WHO, 1996, N132 WHO