Movement loci of selected points on the femoral head for individual total hip arthroplasty patients using three-dimensional computer simulation

被引:23
作者
Bennett, DB [1 ]
Orr, JF [1 ]
Baker, R [1 ]
机构
[1] Queens Univ Belfast, Sch Mech & Mfg Engn, Belfast, Antrim, North Ireland
关键词
total hip arthroplasty; gait analysis; computer simulation; ultra-high-molecular-weight polyethylene wear;
D O I
10.1054/arth.2000.9195
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Wear of ultra-high-molecular-weight polyethylene (UHMWPE) and the subsequent adverse tissue reaction to the wear particles has been cited as the predominant problem affecting total joint arthroplasties. Wear of the UHMWPE acetabular cup in total hip arthroplasties (THAs) is influenced by the sliding distance and direction of individual points on the femoral head, which has as yet been ascertained only for normal subjects. This study seeks to determine the trajectory of specified points on the femoral head for individual THA patients and the distances traversed by these points. A computer program was designed to use gait data from THA patients to simulate the motion of these points. Gait analysis was performed on 19 THA patients at a period of 5 years after operation. The orientation of the acetabular cup was ascertained from radiographs to determine the position of the points on the head most involved in the wear process. The loci of the points differed widely in size, shape, and direction between subjects. The largest average distance traversed was 140% greater than the smallest average distance traversed. Shorter longitudinal paths would tend to cause less wear than larger, wider paths, which cross a greater number of adjacent paths.
引用
收藏
页码:909 / 915
页数:7
相关论文
共 12 条
[1]
AMSTUTZ HC, 1992, CLIN ORTHOP RELAT R, P7
[2]
Bragdon C R, 1996, Proc Inst Mech Eng H, V210, P157, DOI 10.1243/PIME_PROC_1996_210_408_02
[3]
THE SYNOVIAL-LIKE MEMBRANE AT THE BONE-CEMENT INTERFACE IN LOOSE TOTAL HIP REPLACEMENTS AND ITS PROPOSED ROLE IN BONE LYSIS [J].
GOLDRING, SR ;
SCHILLER, AL ;
ROELKE, M ;
ROURKE, CM ;
ONEILL, DA ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1983, 65 (05) :575-584
[4]
SEVERE OSTEOLYSIS OF THE PELVIS IN ASSOCIATION WITH ACETABULAR REPLACEMENT WITHOUT CEMENT [J].
MALONEY, WJ ;
PETERS, P ;
ENGH, CA ;
CHANDLER, H .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (11) :1627-1635
[5]
MCKELLOP HA, 1995, CLIN ORTHOP RELAT R, P3
[6]
FRICTION AND MOLECULAR STRUCTURE - BEHAVIOR OF SOME THERMOPLASTICS [J].
POOLEY, CM ;
TABOR, D .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1972, 329 (1578) :251-&
[7]
Loci of movement of selected points on the femoral head during normal gait - Three-dimensional computer simulation [J].
Ramamurti, BS ;
Bragdon, CR ;
OConnor, DO ;
Lowenstein, JD ;
Jasty, M ;
Estok, DM ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 1996, 11 (07) :845-852
[8]
Type of motion and lubricant in wear simulation of polyethylene acetabular cup [J].
Saikko, V ;
Ahlroos, T .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H4) :301-310
[9]
PERIPROSTHETIC BONE LOSS IN TOTAL HIP-ARTHROPLASTY - POLYETHYLENE WEAR DEBRIS AND THE CONCEPT OF THE EFFECTIVE JOINT SPACE [J].
SCHMALZRIED, TP ;
JASTY, M ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (06) :849-863
[10]
MEASUREMENT AND EFFECTS OF FRICTION AND WEAR IN ARTIFICIAL HIP JOINTS [J].
WALKER, PS ;
SALVATI, E .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1973, 7 (03) :327-342