Lipophilic benzamide and anilide derivatives as high-performance liquid chromatography internal standards: application to sirolimus (rapamycin) determination

被引:22
作者
Ferron, GM [1 ]
Conway, WD [1 ]
Jusko, WJ [1 ]
机构
[1] SUNY Buffalo, Dept Pharmaceut, Buffalo, NY 14260 USA
来源
JOURNAL OF CHROMATOGRAPHY B | 1997年 / 703卷 / 1-2期
关键词
internal standard; benzamide derivatives; anilide derivatives; sirolimus; rapamycin;
D O I
10.1016/S0378-4347(97)00415-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Finding a suitable internal standard in reversed-phase high-performance liquid chromatography is often difficult. A general approach for selecting and synthesizing the proper internal standard is presented and applied to a validated method for quantitation of sirolimus in several biological matrices. A series of fifteen N-alkylbenzamides, N-alkyltoluamides and N-alkanoylanilines with a log P range of 3.51 to 6.68 were synthesized as internal standards; N-undecyl-o-toluamide was evaluated most extensively. Sirolimus quantitation involves a simple sample clean-up procedure followed by isocratic chromatography on a heated C-18 analytical column with an 70% methanol-water mobile phase and ultraviolet detection at 278 nm. This method was linear from 2.5 to 200 ng with a limit of quantitation of 2.5 ng using a 1-ml blood sample. Sirolimus recovery was above 72.1%. The intra-day and inter-day coefficients of variation were less than 11.7%. Several drugs and sirolimus metabolites do not interfere with the analysis. This method was used to measure sirolimus in blood from rats, rabbits and humans. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:243 / 251
页数:9
相关论文
共 20 条
[1]  
Baumann E., 1886, CHEM BER-RECL, V19, P3218
[2]  
CHRISTIANS U, 1992, DRUG METAB DISPOS, V20, P186
[3]   15 YEARS OF OPERATION OF A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR PREDNISOLONE, CORTISOL AND PREDNISONE IN PLASMA [J].
JUSKO, WJ ;
PYSZCZYNSKI, NA ;
BUSHWAY, MS ;
DAMBROSIO, R ;
MIS, SM .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 658 (01) :47-54
[4]   PHENONES - FAMILY OF COMPOUNDS BROADLY APPLICABLE TO USE AS INTERNAL STANDARDS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - APPLICATION TO ANALYSIS OF CARBOFURAN [J].
KIKTA, EJ ;
STANGE, AE .
JOURNAL OF CHROMATOGRAPHY, 1977, 138 (01) :41-45
[5]  
LEO A, 1993, CHEM REV, V5, P1281
[6]   APPLICATION OF A VARIANCE-STABILIZING TRANSFORMATION APPROACH TO LINEAR-REGRESSION OF CALIBRATION LINES [J].
MCLEAN, AM ;
RUGGIRELLO, DA ;
BANFIELD, C ;
GONZALEZ, MA ;
BIALER, M .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1990, 79 (11) :1005-1008
[7]  
Morris R.E., 1992, Transpl. Rev, V6, P39, DOI DOI 10.1016/S0955-470X(10)80014-X
[8]  
NAPOLI K, 1994, J CHROMATOGR, V645, P111
[9]  
Napoli KL, 1996, CLIN CHEM, V42, P1943
[10]   REVERSIBLE ISOMERIZATION OF RAPAMYCIN DEMONSTRATED BY LIQUID-CHROMATOGRAPHY [J].
NISHIKAWA, T ;
SUZUKI, S ;
OHTANI, H .
JOURNAL OF ANTIBIOTICS, 1994, 47 (12) :1554-1556