Investigation of variance reduction techniques for Monte Carlo photon dose calculation using XVMC

被引:210
作者
Kawrakow, I [1 ]
Fippel, M
机构
[1] Natl Res Council Canada, Inst Natl Measurement Stand, Ottawa, ON K1A 0R6, Canada
[2] Univ Tubingen, Radiol Klin, Abt Med Phys, D-72076 Tubingen, Germany
关键词
D O I
10.1088/0031-9155/45/8/308
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Several variance reduction techniques, such as photon splitting, electron history repetition, Russian roulette and the use of quasi-random numbers are investigated and shown to significantly improve the efficiency of the recently developed XVMC Monte Carlo code for photon beams in radiation therapy. It is demonstrated that it is possible to further improve the efficiency by optimizing transport parameters such as electron energy cut-off, maximum electron energy step size, photon energy cut-off and a cut-off for kerma approximation, without loss of calculation accuracy. These methods increase the efficiency by a factor of up to 10 compared with the initial XVMC ray-tracing technique or a factor of 50 to 80 compared with EGS4/PRESTA. Therefore, a common treatment plan (6 MV photons, 10 x 10 cm(2) field size, 5 mm voxel resolution, 1% statistical uncertainty) can be calculated within 7 min using a single CPU 500 MHz personal computer If the requirement on the statistical uncertainty is relaxed to 2%, the calculation time will be less than 2 min. In addition, a technique is presented which allows for the quantitative comparison of Monte Carlo calculated dose distributions and the separation of systematic and statistical errors. Employing this technique it is shown that XVMC calculations agree with EGSnrc on a sub-per cent level for simulations in the energy and material range of interest for radiation therapy.
引用
收藏
页码:2163 / 2183
页数:21
相关论文
共 17 条
[1]   CALCULATION AND APPLICATION OF POINT SPREAD FUNCTIONS FOR TREATMENT PLANNING WITH HIGH-ENERGY PHOTON BEAMS [J].
AHNESJO, A ;
ANDREO, P ;
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (01) :49-56
[2]  
Berger M.J., 1963, METHODS COMPUT PHYS, P135
[3]  
BIELAJEW AF, 1987, NUCL INSTRUM METH B, V18, P165
[4]  
BIELAJEW AF, 1988, P INT SCH RAD DAM PR, P407
[5]  
Brahme A., 1988, ACTA ONCOL S, V1, P1
[6]   Experimental investigation of a fast Monte Carlo photon beam dose calculation algorithm [J].
Fippel, M ;
Laub, W ;
Huber, B ;
Nüsslin, F .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12) :3039-3054
[7]   Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm [J].
Fippel, M .
MEDICAL PHYSICS, 1999, 26 (08) :1466-1475
[8]  
ICRU, 1992, ICRU Report, P46
[9]   Accurate condensed history Monte Carlo simulation of electron transport. II. Application to ion chamber response simulations [J].
Kawrakow, I .
MEDICAL PHYSICS, 2000, 27 (03) :499-513
[10]   3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC) [J].
Kawrakow, I ;
Fippel, M ;
Friedrich, K .
MEDICAL PHYSICS, 1996, 23 (04) :445-457