Screening for amblyopia in preverbal children with photoscreening photographs - III. Improved grading criteria for hyperopia

被引:14
作者
Tong, PY
Macke, JP
Bassin, RE
Everett, M
Enke-Miyazaki, E
Tielsch, JM
Stager, DR
Parks, MM
Beauchamp, GR
机构
[1] Johns Hopkins Univ Hosp, Wilmer Ophthalmol Inst, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Wilmer Ophthalmol Inst, Baltimore, MD 21218 USA
[3] Johns Hopkins Univ, Dept Mol Biol & Genet, Baltimore, MD 21218 USA
[4] Mt Sinai Med Ctr, Dept Ophthalmol, New York, NY 10029 USA
[5] Ctr Adult Strabismus, Dallas, TX USA
[6] Grene Vis Grp, Wichita, KS USA
[7] Johns Hopkins Univ, Dept Int Hlth, Baltimore, MD USA
[8] Johns Hopkins Univ, Dana Ctr Prevent Ophthalmol, Baltimore, MD USA
[9] Childrens Natl Med Ctr, Dept Ophthalmol, Washington, DC 20010 USA
关键词
D O I
10.1016/S0161-6420(00)00336-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To examine the ability of the Medical Technology and Innovations (MTI), Inc., Photoscreener (Cedar Falls, IA) to detect hyperopia and to improve the photograph grading criteria to screen for amblyopiogenic levels of hyperopia, Design: Cross-sectional study and reanalysis. Participants and Testing In previous work, 392 participants received a complete ophthalmologic examination and were photographed using the MTI Photoscreener. For this study, all 209 participants with normal examination findings (65 children) or hyperopia without anisometropia (144 children) were selected. The data were reanalyzed using modified photograph grading and ophthalmologic examination failure criteria. Potential reasons for why many children with hyperopia passed photoscreening were explored. Main Outcome Measurer We determined whether a study participant would pass or fail screening with a given photograph grading and ophthalmologic examination failure criteria. Results: Most children with hyperopia of +2.00 to +3.50 diopters (D) passed screening with the MTI instrument, in most cases because their photographs lacked bright crescents. When bright crescents in at least two of the four possible meridians were the grading guideline for screening failure and the pediatric ophthalmologists' consensus hyperopia failure criteria (> +3.50 D) were adopted, the sensitivity for hyperopia detection was 100% and the specificity was 88%. Identical results were obtained using the American Academy of Ophthalmology Preferred Practice Pattern hyperopia failure criteria (greater than or equal to +4.50 D). Conclusions: The MTI photograph grading guidelines can be simplified, and the ophthalmologic examination failure criteria for hyperopia can be improved. The presence of a bright crescent in the lower or the left pupillary margin indicate hyperopia in an amblyopiogenic range (> +3.50 D). Ophthalmology 2000,.107. 1630-1636 (C) 2000 by the American Academy of Ophthalmology.
引用
收藏
页码:1630 / 1636
页数:7
相关论文
共 18 条
[1]  
*AM AC OPHTH, 1992, AMBL PREF PRACT PATT
[2]  
BOBIER WR, 1988, AM J OPTOM PHYS OPT, V65, P962
[3]  
FREEDMAN HL, 1992, OPHTHALMOLOGY, V99, P1785
[4]   OPTICS OF PHOTOREFRACTION - ORTHOGONAL AND ISOTROPIC METHODS [J].
HOWLAND, HC ;
BRADDICK, O ;
ATKINSON, J ;
HOWLAND, B .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1983, 73 (12) :1701-1708
[5]  
JAKOBSSON P, 1996, T 23 M EUR STRAB ASS, P25
[6]  
Lennerstrand G, 1996, ACTA OPHTHALMOL SCAN, V74, P42
[7]  
Lewis R C, 1995, J Am Optom Assoc, V66, P429
[8]  
*MED TECHN INC, 1994, MTI PHOT INSTR INT M, P34
[9]  
OTTAR WL, 1995, J PEDIATR OPHTHALMOL, V32, P289
[10]  
*PREV BLINDN AM, 1995, PHOT TRAIN COURS