Speciation of antimony(III) and antimony(V) species by using high-performance liquid chromatography coupled to hydride generation atomic absorption spectrometry

被引:49
作者
Zhang, XR [1 ]
Cornelis, R [1 ]
Mees, L [1 ]
机构
[1] Univ Ghent, Inst Nucl Sci, Analyt Chem Lab, B-9000 Ghent, Belgium
关键词
antimony speciation; high-performance liquid chromatography; hydride generation atomic absorption spectrometry; water samples;
D O I
10.1039/a706621j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniaturized HPLC column (Supelcosil LC-SAX 1, 2 cm x 4.6 mm id) was coupled to HGAAS for the speciation of inorganic Sb-III and Sb-V species in spiked water samples, The baseline separation of these two Sb species was achieved by using aqueous 50 mmol 1(-1) tartrate solution at pH 5.5 as eluent, The retention times were 0.5 and 2.8 min for Sb-V and Sb-III, respectively, The hydrides were generated with 3% NaBH4 and 1.8 mol 1(-1) HCl solutions, The absorbance was Linearly related to the concentration of Sb-V species in the range 2.5-100 mu g 1(-1) (n = 0.9996) and of Sb-III species in the range 5.0-100 mu g 1(-1) (n = 0.9990) with detection limits of 1.0 and 2.0 mu g 1(-1), for Sb-V and Sb-III, respectively. The precision, evaluated by using the relative standard deviation (RSD), was 3.3% and 1.5% (n = 10) for Sb-V and Sb-III at concentrations of 50 mu g 1(-1), and 4.1% and 3.9% (n = 10) at concentrations of 10 mu g 1(-1), respectively, The detection limits achieved in the present work are acceptable for screening samples with respect to the EU drinking and surface water limits (10 mu g 1(-1)), but are not sufficiently sensitive to measure real levels in natural waters, The accuracy of the method was evaluated by the analysis of Sb species in several spiked water samples, as there is yet no certified reference material available.
引用
收藏
页码:205 / 207
页数:3
相关论文
共 24 条
[1]   DETERMINATION OF ANTIMONY(III), ANTIMONY(V), AND METHYLANTIMONY SPECIES IN NATURAL-WATERS BY ATOMIC-ABSORPTION SPECTROMETRY WITH HYDRIDE GENERATION [J].
ANDREAE, MO ;
ASMODE, JF ;
FOSTER, P ;
VANTDACK, L .
ANALYTICAL CHEMISTRY, 1981, 53 (12) :1766-1771
[2]   DETERMINATION OF DISSOLVED INORGANIC ANTIMONY(V) AND ANTIMONY(III) SPECIES IN NATURAL-WATERS BY HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY [J].
APTE, SC ;
HOWARD, AG .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1986, 1 (03) :221-225
[3]   Development of a multi-element hydride generation inductively coupled plasma mass spectrometry procedure for the simultaneous determination of arsenic, antimony and selenium in waters [J].
Bowman, J ;
Fairman, B ;
Catterick, T .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (03) :313-316
[4]   DIRECT VOLATILIZATION SPECTRAL EMISSION TYPE DETECTION SYSTEM FOR NANOGRAM AMOUNTS OF ARSENIC AND ANTIMONY [J].
BRAMAN, RS ;
FOREBACK, CC ;
JUSTEN, LL .
ANALYTICAL CHEMISTRY, 1972, 44 (13) :2195-&
[5]   STUDY OF INORGANIC ARSENIC METHYLATION BY RAT-LIVER INVITRO - RELEVANCE FOR THE INTERPRETATION OF OBSERVATIONS IN MAN [J].
BUCHET, JP ;
LAUWERYS, R .
ARCHIVES OF TOXICOLOGY, 1985, 57 (02) :125-129
[6]   DETERMINATION OF ANTIMONY(III,V) IN NATURAL-WATERS BY SEPARATION AND PRECONCENTRATION ON A THIONALIDE LOADED RESIN FOLLOWED BY NEUTRON-ACTIVATION ANALYSIS [J].
CHWASTOWSKA, J ;
ZMIJEWSKA, W ;
STERLINSKA, E .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1995, 196 (01) :3-9
[7]   APPLICABILITY OF ANODIC-STRIPPING VOLTAMMETRY AND GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY TO THE DETERMINATION OF ANTIMONY IN BIOLOGICAL MATRICES - A COMPARATIVE-STUDY [J].
COSTANTINI, S ;
GIORDANO, R ;
RIZZICA, M ;
BENEDETTI, F .
ANALYST, 1985, 110 (11) :1355-1359
[8]   Antimony speciation in freshwater plant extracts by using hydride generation gas chromatography mass spectrometry [J].
Dodd, M ;
Pergantis, SA ;
Cullen, WR ;
Li, H ;
Eigendorf, GK ;
Reimer, KJ .
ANALYST, 1996, 121 (02) :223-228
[9]  
ELINDER DG, 1979, HDB TOXICOLOGY METAL, P283
[10]  
GARCIA AM, 1995, FRESEN J ANAL CHEM, V353, P128