Utility of intravenously administered contrast material at CT colonography

被引:139
作者
Morrin, MM
Farrell, RJ
Kruskal, JB
Reynolds, K
McGee, JB
Raptopoulos, V
机构
[1] Harvard Univ, Sch Med, Dept Radiol, Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Dept Gastroenterol, Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
关键词
colon; CT; colon neoplasms; colon neoplasms diagnosis; computed tomography (CT); contrast media;
D O I
10.1148/radiology.217.3.r00nv42765
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine if intravenously administered contrast material improves overall reader confidence in the assessment of the colon, large-bowel wall conspicuity, and diagnostic accuracy in the detection of colorectal polyps and cancers at computed tomographic (CT) colonography. MATERIALS AND METHODS: Two hundred patients underwent CT colonography in both supine and prone positions. A five-point scale was used to assess the effect of contrast enhancement on overall reader confidence and bowel wall conspicuity. Eighty-one patients underwent CT colonography with complete colonoscopic or surgical correlation; diagnostic accuracy was compared in 48 patients who received contrast material and 33 who did not. RESULTS: Bowel preparation was ideal in 38 (19%) of 200 patients. Enhanced prone CT images had significantly better scores for reader confidence (4.9 +/- 0.1 vs 4.6 +/- 0.1, P < .005) and bowel wall conspicuity (4.6 +/- 0.2 vs 4.2 +/- 0.2, P < .005) compared with those of nonenhanced prone images despite no significant difference in bowel distention (3.8 +/- 0.2 vs 3.9 +/- 0.1, P = .8). Enhancement significantly improved the ability to depict medium (6-9-mm) polyps (75% vs 58%, P < .05). Three large (10-19-mm) polyps were detected only with contrast enhancement; two remained submerged despite dual positioning. CONCLUSION: The use of intravenously administered contrast material significantly improved reader confidence in the assessment of bowel wall conspicuity and the ability of CT colonography to depict medium polyps in suboptimally prepared colons.
引用
收藏
页码:765 / 771
页数:7
相关论文
共 21 条
[1]   Technical report: Spiral CT pneumocolon for suspected colonic neoplasms [J].
Amin, Z ;
Boulos, PB ;
Lees, WR .
CLINICAL RADIOLOGY, 1996, 51 (01) :56-61
[2]   CT colonography: Value of scanning in both the supine and prone positions [J].
Chen, SC ;
Lu, DSK ;
Hecht, JR ;
Kadell, BM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (03) :595-599
[3]   CT colonography with three-dimensional problem solving for detection of colonic polyps [J].
Dachman, AH ;
Kuniyoshi, JK ;
Boyle, CM ;
Samara, Y ;
Hoffmann, KR ;
Rubin, DT ;
Hanan, I .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (04) :989-995
[4]   CT colonography: Potential pitfalls and problem-solving techniques [J].
Fletcher, JG ;
Johnson, CD ;
MacCarty, RL ;
Welch, TJ ;
Reed, JE ;
Hara, AK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) :1271-1278
[5]   Impact of sedation and resident teaching on complications of colonoscopy [J].
Galandiuk, S ;
Ahmad, P .
DIGESTIVE SURGERY, 1998, 15 (01) :60-63
[6]   Detection of colorectal polyps with CT colography: Initial assessment of sensitivity and specificity [J].
Hara, AK ;
Johnson, CD ;
Reed, JE ;
Ahlquist, DA ;
Nelson, H ;
MacCarty, RL ;
Harmsen, WS ;
Ilstrup, DM .
RADIOLOGY, 1997, 205 (01) :59-65
[7]  
HARA AK, 1997, GASTROENTEROLOGY, V112, P575
[8]   Helical CT pneumocolon to assess colonic tumors: Radiologic-Pathologic correlation [J].
Harvey, CJ ;
Amin, Z ;
Hare, CMB ;
Gillams, AR ;
Novelli, MR ;
Boulos, PB ;
Lees, WR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (06) :1439-1443
[9]   Computed tomography colonography (virtual colonoscopy): a new method for colorectal screening [J].
Johnson, CD ;
Ahlquist, DA .
GUT, 1999, 44 (03) :301-305
[10]   Adverse reactions to nonionic iodine in contrast-enhanced computed tomography: usefulness of monitoring vital signs [J].
Kurabayashi, T ;
Ida, M ;
Fukayama, H ;
Ohbayashi, N ;
Yoshino, N ;
Sasaki, T .
DENTOMAXILLOFACIAL RADIOLOGY, 1998, 27 (04) :199-202