Assessment of myocardial lesion size during in vitro radio frequency catheter ablation

被引:13
作者
He, DS [1 ]
Bosnos, M [1 ]
Mays, MZ [1 ]
Marcus, F [1 ]
机构
[1] Univ Arizona, Med Ctr, Sarver Heart Ctr, Tucson, AZ 85724 USA
关键词
arrhythmia; catheter ablation; impedance;
D O I
10.1109/TBME.2003.812161
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
We report our experience with a system that utilizes changes in several biophysical characteristics of cardiac tissue to determine lesion formation and to estimate lesion size both on and off-line in vitro during radio frequency (RF) energy delivery. We analyzed the reactive and resistive components of tissue impedance and tracked the change of phase angle during RF ablation. We correlated the amount of tissue damage with these and other biophysical parameters and compared them with off-line analysis. We found that there are irreversible changes in the reactive and resistive components of impedance that occurred during tissue ablation. The irreversible changes of these components are greater in, magnitude, and correlate better with the size of lesions than that of impedance alone that is currently used. Numerically, the best single on-line and off-line correlation for combined perpendicular and parallel electrode orientation was with phase angle. On-line and off-line capacitance and susceptance correlations were essentially similar suggesting that they may be useful as lesion size predictors, given these parameter's persistent change without temperature sensitivity. This study indicates that it is technically feasible to assess lesion formation using biophysical parameters.
引用
收藏
页码:768 / 776
页数:9
相关论文
共 14 条
[1]
ASSESSMENT OF EFFECTS OF A RADIOFREQUENCY ENERGY-FIELD AND THERMISTOR LOCATION IN AN ELECTRODE CATHETER ON THE ACCURACY OF TEMPERATURE-MEASUREMENT [J].
BLOUIN, LT ;
MARCUS, FI ;
LAMPE, L .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (05) :807-813
[2]
Catheter ablation of accessory pathways, atrioventricular nodal reentrant tachycardia, and the atrioventricular junction - Final results of a prospective, multicenter clinical trial [J].
Calkins, H ;
Yong, P ;
Miller, JM ;
Olshansky, B ;
Carlson, M ;
Saul, JP ;
Huang, SKS ;
Liem, LB ;
Klein, LS ;
Moser, SA ;
Bloch, DA ;
Gillette, P ;
Prystowsky, E .
CIRCULATION, 1999, 99 (02) :262-270
[3]
Comparison of irrigated electrode designs for radiofrequency ablation of myocardium [J].
Demazumder, D ;
Mirotznik, MS ;
Schwartzman, D .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2001, 5 (04) :391-400
[4]
Temperature monitoring during radiofrequency ablation [J].
Dinerman, JL ;
Berger, RD ;
Calkins, H .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1996, 7 (02) :163-173
[5]
EARLY PHASE ACUTE MYOCARDIAL INFARCT SIZE QUANTIFICATION - VALIDATION OF THE TRIPHENYL TETRAZOLIUM CHLORIDE TISSUE ENZYME STAINING TECHNIQUE [J].
FISHBEIN, MC ;
MEERBAUM, S ;
RIT, J ;
LANDO, U ;
KANMATSUSE, K ;
MERCIER, JC ;
CORDAY, E ;
GANZ, W .
AMERICAN HEART JOURNAL, 1981, 101 (05) :593-600
[6]
Non-pharmacological treatment of supraventricular arrhythmias [J].
Josephson, ME ;
Schibgilla, VH .
EUROPEAN HEART JOURNAL, 1996, 17 :26-34
[7]
LILLIE RD, 1977, HJ CONNS BIOL STAINS, P225
[8]
ULTRASTRUCTURAL OBSERVATIONS IN THE MYOCARDIUM BEYOND THE REGION OF ACUTE COAGULATION NECROSIS FOLLOWING RADIOFREQUENCY CATHETER ABLATION [J].
NATH, S ;
REDICK, JA ;
WHAYNE, JG ;
HAINES, DE .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1994, 5 (10) :838-845
[9]
BIOPHYSICS AND PATHOLOGY OF CATHETER ENERGY DELIVERY SYSTEMS [J].
NATH, S ;
HAINES, DE .
PROGRESS IN CARDIOVASCULAR DISEASES, 1995, 37 (04) :185-204
[10]
NATH S, 1997, CARDIAC ELECTROPHYSI, V4, P407