The bisurface total knee replacement: A unique design for flexion - Four-to-nine-year follow-up study

被引:88
作者
Akagi, M [1 ]
Nakamura, T [1 ]
Matsusue, Y [1 ]
Ueo, T [1 ]
Nishijyo, K [1 ]
Ohnishi, E [1 ]
机构
[1] Kyoto Univ, Dept Orthopaed Surg, Kyoto, Japan
关键词
D O I
10.2106/00004623-200011000-00017
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The Bisurface knee prosthesis was designed in 1989 to improve knee flexion without affecting the durability of the prosthesis. The prosthesis has a unique ball-and-socket joint in the midposterior portion of the femoral and tibial components, which functions as a posterior Stabilizing cam mechanism and causes femoral: rollback, The femoral component was made of alumina ceramic, The purpose of this study was to review the clinical results of the first 223 arthroplasties performed with this prosthesis in order to assess whether this new implant had achieved its design objectives. Methods: From December 1989 to May 1994, all patients who were scheduled for primary total knee arthroplasty were enrolled in a prospective study of the Bisurface: knee. The patients were evaluated clinically according to The Hospital for Special Surgery knee-rating-system and with a self-administered questionnaire, and they were evaluated radiographically according to the system of the Knee Society. Kaplan-Meier survivorship analysis was performed,vith revision of the knee or recommendation for revision as the end point. Results: One hundred and sixty-six patients treated with a total of 223 consecutive primary total knee arthroplasties were enrolled in the study, and 182 knees were followed for 3.9 to 9.0 years (mean, 5.8 years). Preoperatively, the mean Hospital for Special Surgery knee scope was 44.5 points. At the time of latest followup, the mean knee score was 86.3 points. The mean preoperative and postoperative ranges of flexion were 119 and 124 degrees, respectively. The patients, even those with. a good preoperative range of motion, rarely lost deep flexion of the knee after the procedure. A revision operation was performed in eight knees (because of infection in five, instability in two, and breakage of the peg of the patellar component in one). Two knees had recurrent medial-lateral subluxations of the femorotibial articulation, which were treated nonoperatively, No prosthesis had loosened aseptically and no alumina ceramic femoral component had broken by the time of latest follow-up. The rate of survival of the implant was 94 percent (95 percent confidence interval, 90 to 98 percent) at six years. According to the patient questionnaires, 20 percent of the knees sometimes felt loose in daily living activities, which prompted us to improve the intrinsic stability of the prosthesis by improving the congruity of the ball-and-socket joint. Conclusions: Total knee arthroplasty with the Bisurface prosthesis resulted in an excellent range of motion and a high level of satisfaction with the operation; the durability of the prosthesis is promising.
引用
收藏
页码:1626 / 1633
页数:8
相关论文
共 33 条
[1]  
Akagi Masao, 1997, Bulletin Hospital for Joint Diseases, V56, P225
[2]  
BEIGHT JL, 1994, CLIN ORTHOP RELAT R, P139
[3]  
BLUNN GW, 1991, CLIN ORTHOP RELAT R, P253
[4]  
Cohen B, 1992, J Arthroplasty, V7, P161, DOI 10.1016/0883-5403(92)90010-N
[5]   CERAMIC BEARING SURFACES IN TOTAL ARTIFICIAL JOINTS - RESISTANCE TO 3RD BODY WEAR DAMAGE FROM BONE-CEMENT PARTICLES [J].
COOPER, JR ;
DOWSON, D ;
FISHER, J ;
JOBBINS, B .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1991, 15 (02) :63-67
[6]  
DAVIDSON JA, 1994, BIO-MED MATER ENG, V4, P213
[7]  
EWALD FC, 1989, CLIN ORTHOP RELAT R, P9
[8]  
Galinat B J, 1988, J Arthroplasty, V3, P363, DOI 10.1016/S0883-5403(88)80039-1
[9]  
GEBHARD JS, 1990, CLIN ORTHOP RELAT R, P225
[10]   FACTORS AFFECTING THE RANGE OF MOVEMENT OF TOTAL KNEE ARTHROPLASTY [J].
HARVEY, IA ;
BARRY, K ;
KIRBY, SPJ ;
JOHNSON, R ;
ELLOY, MA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (06) :950-955