摘要
We have analyzed five p53 single point mutations by single strand conformation polymorphism using capillary electrophoresis (CE-SSCP) and have compared these measurements to measurements obtained by slab gel electrophoresis (SG-SSCP). PCR primers were used for amplification of specific exons for mutation detection. 5' Primers were labeled with FAM (5-carboxyfluorescein) and 3' primers were labeled with JOE (2',7'-dimethoxy-4',5'-dichloro-6-carboxyfluorescein). CE-SSCP was performed using the Perkin Elmer ABI PRISM(TM) 310 Genetic Analyzer with GeneScan(TM) Software and the Beckman P/ACE(TM) 5510 CE equipped for laser-induced fluorescence detection. Although the shifts in migration times for the p53 mutations relative to the corresponding wild-type strands could be successfully detected by either SG or CE analysis, the individual electrophoresis run times were about tenfold faster and more automated with capillary electrophoresis. The CE-SSCP measurements were performed at temperatures ranging from 10 to 60 degrees C on a prototype instrument. For mutations measured at ambient temperature (25 degrees C), characteristic shifts in direction and magnitude were observed in the migration times of both strands of all mutations relative to the wild type. This demonstrated the ability of CE at ambient temperature to resolve these mutations. However, the magnitute and direction of shifts in migration time varied with temperature in a discrete pattern for each mutation and resulted in a temperature-specific profile for each mutation. This demonstrated that extended temperature control will be an important advantage in resolving single point mutations by CE-SSCP. In addition, by using CE, discrete intra-strand isoforms could be easily observed at different temperatures. The combination of mutation-specific temperature profiling and analysis of isoforms by CE-SSCP should be of help to the diagnostic community in the detection of genetic mutations.
引用
收藏
页码:172 / 179
页数:8
相关论文
共 18 条
  • [1] Analysis of single-strand DNA conformation polymorphism by capillary electrophoresis
    Arakawa, H
    Nakashiro, S
    Maeda, M
    Tsuji, A
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1996, 722 (1-2) : 359 - 368
  • [2] ELLISON J, 1993, BIOTECHNIQUES, V15, P684
  • [3] CAPILLARY ELECTROPHORESIS OF DNA - POTENTIAL UTILITY FOR CLINICAL DIAGNOSES
    FELMLEE, TA
    ODA, RP
    PERSING, DA
    LANDERS, JP
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 717 (1-2) : 127 - 137
  • [4] SINGLE-STRAND CONFORMATIONAL POLYMORPHISM USING CAPILLARY ELECTROPHORESIS WITH 2-DYE LASER-INDUCED FLUORESCENCE DETECTION
    HEBENBROCK, K
    WILLIAMS, PM
    KARGER, BL
    [J]. ELECTROPHORESIS, 1995, 16 (08) : 1429 - 1436
  • [5] P53 MUTATIONS IN HUMAN CANCERS
    HOLLSTEIN, M
    SIDRANSKY, D
    VOGELSTEIN, B
    HARRIS, CC
    [J]. SCIENCE, 1991, 253 (5015) : 49 - 53
  • [6] COLD SSCP - A SIMPLE, RAPID AND NONRADIOACTIVE METHOD FOR OPTIMIZED SINGLE-STRAND CONFORMATION POLYMORPHISM ANALYSES
    HONGYO, T
    BUZARD, GS
    CALVERT, RJ
    WEGHORST, CM
    [J]. NUCLEIC ACIDS RESEARCH, 1993, 21 (16) : 3637 - 3642
  • [7] One-tube post-PCR fluorescent labeling of DNA fragments
    Inazuka, M
    Tahira, T
    Hayashi, K
    [J]. GENOME RESEARCH, 1996, 6 (06): : 551 - 557
  • [8] IWAHANA H, 1994, BIOTECHNIQUES, V16, P296
  • [9] CONSTANT DENATURANT CAPILLARY ELECTROPHORESIS (CDCE) - A HIGH-RESOLUTION APPROACH TO MUTATIONAL ANALYSIS
    KHRAPKO, K
    HANEKAMP, JS
    THILLY, WG
    BELENKII, A
    FORET, F
    KARGER, BL
    [J]. NUCLEIC ACIDS RESEARCH, 1994, 22 (03) : 364 - 369
  • [10] On-line melting of double-stranded DNA for analysis of single-stranded DNA using capillary electrophoresis
    Kuypers, AWHM
    Linssen, PCM
    Willems, PMW
    Mensink, EJBM
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1996, 675 (02): : 205 - 211