摘要
Objective: The impact of storage solution composition on graft performance was evaluated following perfusion with either Euro-Collins (EC), low potassium Euro-Collins (rEC), low potassium dextran (LPD) or University of Wisconsin solution (UW) after brief (2 h) and extended ischemia (16 h) in an acute double lung transplantation model in the rat. Methods: Following Bush perfusion and ischemia the lungs were implanted in recipient rats allowing serial assessment of graft pulmonary vascular resistance (PVR) and alveolar arterial oxygen difference (AaDO(2)) during 120 min of reperfusion. Graft dynamic lung compliance (DLC) was determined by separate ventilation. Final evaluation included weight gain and histology. Results: After extended ischemia LPD provided superior graft function in respect to DLC (repeated measures ANOVA; LPD versus rEC P < 0.05; versus EC P < 0.03; versus UW P < 0.05) and AaDO(2) (LPD versus rEC P < 0.04; versus EC P < 0.006). The PVR was significantly lower in LPD versus UW (P < 0.05). At the end of reperfusion the weight increase amounted to 229 +/- 49% in rEC, 207 +/- 22% in EC, 115 +/- 22% in UW and 87 +/- 17% in LPD (LPD versus rEC P < 0.01, LPD versus EC P < 0.001). The type of preservation solution used had little impact on graft function after 2 h ischemia. Conclusions: Low potassium dextran provides superior graft function after extended ischemia. After short ischemia the type of preservation solution used in this study had little impact on global lung function. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:771 / 780
页数:10
相关论文
共 29 条
[1]  
BARTLETT GR, 1959, J BIOL CHEM, V234, P466
[2]   IMPAIRMENT OF VASCULAR ENDOTHELIAL FUNCTION BY HIGH-POTASSIUM STORAGE SOLUTIONS [J].
CHAN, BBK ;
KRON, IL ;
FLANAGAN, TL ;
KERN, JA ;
HOBSON, CE ;
TRIBBLE, CG .
ANNALS OF THORACIC SURGERY, 1993, 55 (04) :940-945
[3]  
COOPER JD, 1986, NEW ENGL J MED, V314, P1140
[4]  
GROSJEAN O, 1972, ACTA CHIR BELG, V5, P321
[5]  
HARDESTY RL, 1993, J THORAC CARDIOV SUR, V105, P660
[6]   Double-lung transplantation in the rat: An acute, syngeneic in situ model [J].
Hausen, B ;
Demertzis, S ;
Schroder, F ;
Beuke, M ;
Schafers, HJ .
ANNALS OF THORACIC SURGERY, 1996, 61 (01) :184-189
[7]   Donor pretreatment with intravenous prostacyclin versus inhaled nitric oxide in experimental lung transplantation [J].
Hausen, B ;
Muller, P ;
Bahra, M ;
Ramsamooj, R ;
Hewitt, CW .
TRANSPLANTATION, 1996, 62 (12) :1714-1719
[8]   The importance of static lung inflation during organ storage - The impact of varying intervals in a double lung rat transplantation model [J].
Hausen, B ;
Ramsamooj, R ;
Hewitt, CW ;
Schroder, F ;
Beuke, M ;
Poets, CF ;
Schafers, HJ .
TRANSPLANTATION, 1996, 62 (12) :1720-1725
[9]  
HIDALGO MA, 1995, INT J EXP PATHOL, V76, P43
[10]  
HIRT SW, 1992, J HEART LUNG TRANSPL, V11, P656