Determination of L-ascorbic acid in human serum by chemiluminescence based on hydrogen peroxide-sodium hydrogen carbonate-CdSe/CdS quantum dots system

被引:142
作者
Chen, Hui [1 ,2 ,3 ]
Li, Ruibo [1 ,2 ,3 ]
Lin, Ling [3 ]
Guo, Guangsheng [3 ]
Lin, Jin-Ming [1 ,2 ]
机构
[1] Tsinghua Univ, Anal Ctr, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Dept Chem, Beijing 100084, Peoples R China
[3] Beijing Univ Chem Technol, State Key Lab Chem Resource Engn, Beijing 100029, Peoples R China
基金
中国国家自然科学基金;
关键词
Chemiluminescence; Flow injection; L-Ascorbic acid; Human serum; ENERGY-TRANSFER; SPECTROPHOTOMETRIC DETERMINATION; LIQUID-CHROMATOGRAPHY; ONLINE PREPARATION; AQUEOUS-SOLUTION; SINGLET OXYGEN; VITAMIN-C; PEROXYMONOCARBONATE; NANOCRYSTALS; CDTE;
D O I
10.1016/j.talanta.2010.03.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present work, a strongly chemiluminescence (CL) from the mixing of hydrogen peroxide (H2O2), hydrogen carbonate (HCO3-) and CdSe/CdS quantum clots (QDs) was observed. The addition of trace amount of L-ascorbic acid into the CL system caused significant quenching luminescence intensity. Based on this phenomenon, a flow injection CL analysis system for the determination of L-ascorbic acid was developed The CL reaction conditions. such as mixing orders and concentrations of CL reagents, flow rates. pH, and particle size of quantum dots have been optimized The CL intensity and the concentration of L-ascorbic acid have a good linear relationship in the ranges of 1.0 x 10(-7)-1.0 x 10(-4) mol L-1 (R-2=0 9916) The limit of detection for L-ascorbic acid is 67 x 10(-9) mol L-1 (S/N =3) This method has been successfully applied to determine L-ascorbic acid in human serum. The recoveries for the real samples were from 83% to 111% and the variance coefficient was <5 3% for intra- and inter-assay precision A possible mechanism of the CL system was proposed according to results of the kinetic curves of CdSe/CdS QDs in NaHCO3-H2O2 CL system, the spectra of CL. fluorescent. UV-visible and ESR. Superoxide ion radical (O-center dot(2)-) and hydroxide radical ((OH)-O-center dot) were generated between the reaction of NaHCO3 and H2O2, which were the key intermediates for the production of hole, electron-injected CdSe/CdS QDs and the CL emission. (C) 2010 Elsevier B.V All rights reserved.
引用
收藏
页码:1688 / 1696
页数:9
相关论文
共 39 条
[1]  
ADRIANI PL, 1998, ANAL BIOCHEM, V263, P176
[2]   Non-spectrophotometric methods for the determination of Vitamin C [J].
Arya, SP ;
Mahajan, M ;
Jain, P .
ANALYTICA CHIMICA ACTA, 2000, 417 (01) :1-14
[3]   REACTIVITY OF HO2/O-2 RADICALS IN AQUEOUS-SOLUTION [J].
BIELSKI, BHJ ;
CABELLI, DE ;
ARUDI, RL ;
ROSS, AB .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1985, 14 (04) :1041-1100
[5]   High-affinity sodium-vitamin C co-transporters (SVCT) expression in embryonic mouse neurons [J].
Castro, M ;
Caprile, T ;
Astuya, A ;
Millán, C ;
Reinicke, K ;
Vera, JC ;
Vásquez, O ;
Aguayo, LG ;
Nualart, F .
JOURNAL OF NEUROCHEMISTRY, 2001, 78 (04) :815-823
[6]   Quantum dot bioconjugates for ultrasensitive nonisotopic detection [J].
Chan, WCW ;
Nie, SM .
SCIENCE, 1998, 281 (5385) :2016-2018
[7]   MASS SPECTROMETRIC EVIDENCE FOR EXISTENCE OF 1,2-DIOXETANEDIONE (CARBON DIOXIDE DIMER) . A CHEMILUMINESCENT INTERMEDIATE [J].
CORDES, HF ;
RICHTER, HP ;
HELLER, CA .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1969, 91 (25) :7209-&
[8]  
DEMAS JN, 1971, J PHYS CHEM-US, V75, P991, DOI 10.1021/j100678a001
[9]   Determination of ascorbic acid and carotenoids in food commodities by liquid chromatography with mass spectrometry detection [J].
Frenich, AG ;
Torres, MEH ;
Vega, AB ;
Vidal, JLM ;
Bolaños, PP .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2005, 53 (19) :7371-7376
[10]   RED CHEMILUMINESCENCE OF MOLECULAR OXYGEN IN AQUEOUS SOLUTION [J].
KHAN, AU ;
KASHA, M .
JOURNAL OF CHEMICAL PHYSICS, 1963, 39 (08) :2105-&