Digital stereo image analyzer for generating automated 3-D measures of optic disc deformation in glaucoma

被引:56
作者
Corona, E
Mitra, S
Wilson, M
Krile, T
Kwon, YH
Soliz, P
机构
[1] Texas Tech Univ, Dept Elect & Comp Engn, Comp Vis & Image Anal Lab, Lubbock, TX 79409 USA
[2] Kestrel Corp, Albuquerque, NM 87109 USA
关键词
glaucoma; isodisparity contour; new three-dimensional (3-D) metrics of optic nerve head; stereo optic disc photography;
D O I
10.1109/TMI.2002.806293
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The major limitations of precise evaluation of retinal structures in present clinical situations are the lack of standardization, the inherent subjectivity involved in the interpretation of retinal images, and intra- as well as interobserver variability. While evaluating optic disc deformation in glaucoma, these limitations could be overcome by using advanced digital image analysis techniques to generate precise metrics from stereo optic disc image pairs. A digital stereovision system for visualizing the topography of the optic nerve head from stereo optic disc images is presented. We have developed an algorithm, combining power cepstrum and zero-mean-normalized cross correlation techniques, which extracts depth information using coarse-to-fine disparity between corresponding windows in a stereo pair. The gray level encoded sparse disparity matrix is subjected to a cubic B-spline operation to generate smooth representations of the optic cup/disc surfaces and new three-dimensional (3-D) metrics from isodisparity contours. Despite the challenges involved in 3-D surface recovery, the robustness of our algorithm in finding disparities within the constraints used has been validated using stereo pairs with known disparities. In a preliminary longitudinal study of glaucoma patients, a strong correlation is found between the computer-generated quantitative cup/disc volume metrics and manual metrics commonly used in a clinic. The computer generated new metrics, however, eliminate the subjective variability and greatly reduce the time and cost involved in manual metric generation in follow-up studies of glaucoma.
引用
收藏
页码:1244 / 1253
页数:10
相关论文
共 32 条
[1]   A SURVEY OF IMAGE REGISTRATION TECHNIQUES [J].
BROWN, LG .
COMPUTING SURVEYS, 1992, 24 (04) :325-376
[3]  
CHANDRAN V, 1987, P TOP M NON ASS VIS, P26
[4]  
CORONA E, 2002, INT SOC OPT ENG SPIE
[5]   VARIABILITY OF DEPTH MEASUREMENTS OF THE OPTIC-NERVE HEAD AND PERIPAPILLARY RETINA WITH COMPUTERIZED IMAGE-ANALYSIS [J].
DANDONA, L ;
QUIGLEY, HA ;
JAMPEL, HD .
ARCHIVES OF OPHTHALMOLOGY, 1989, 107 (12) :1786-1792
[6]  
GREANEY M, 2000, EUR GLAUC SOC M ASS
[7]   OPTICAL COHERENCE TOMOGRAPHY OF THE HUMAN RETINA [J].
HEE, MR ;
IZATT, JA ;
SWANSON, EA ;
HUANG, D ;
SCHUMAN, JS ;
LIN, CP ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (03) :325-332
[8]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[9]   POWER CEPSTRUM AND SPECTRUM TECHNIQUES APPLIED TO IMAGE REGISTRATION [J].
LEE, DJ ;
KRILE, TF ;
MITRA, S .
APPLIED OPTICS, 1988, 27 (06) :1099-1106
[10]  
LEE DJ, 1987, P SOC PHOTOOPT INSTR, V829, P293