Analysis of cortisol with a flow displacement immunoassay

被引:22
作者
Kaptein, WA
Zwaagstra, JJ
Venema, K
Ruiters, MHJ
Korf, J
机构
[1] Univ Groningen, Dept Biol Psychiat, NL-9713 EZ Groningen, Netherlands
[2] Univ Groningen, Biomed Technol Ctr, NL-9713 EZ Groningen, Netherlands
关键词
immunosensor; cortisol; displacement; analyte-enzyme conjugate; electrochemical detection;
D O I
10.1016/S0925-4005(97)00271-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study investigates a flow immunoassay for cortisol based on displacement of labelled antigen analogues from immobilised antibodies. On a displacement column, two antibodies with different affinities were immobilised on protein-A Sepharose, and a construct of cortisol and horseradish peroxidase (cort-HRP) was associated to the antibodies. Perfusion of the column with cortisol displaced a proportional amount of cort-HRP. On-line detection was performed with an electrochemical detector measuring cort-HRP directly in a flow injection system. For investigating some characteristics of the displacement system, cort-HRP was also detected off-line, with a substrate for HRP, which changes OD492. We tested our system in buffer as well in serum for 2 days at a flow of 4-6 mu l min(-1). Analysis of the data show a detectable displacement signal at physiological cortisol concentrations. The specificity, stability of the columns and the influence of the antibody affinity were studied. (C) 1997 Elsevier Science S.A.
引用
收藏
页码:63 / 69
页数:7
相关论文
共 23 条
[1]   A PIEZOELECTRIC IMMUNOSENSOR FOR THE DETECTION OF CORTISOL [J].
ATTILI, BS ;
SULEIMAN, AA .
ANALYTICAL LETTERS, 1995, 28 (12) :2149-2159
[2]  
DEBOER J, 1991, PFLUG ARCH EUR J PHY, V419, P1
[3]   STANDARDIZATION OF HAPTEN IMMUNOPROCEDURES - TOTAL CORTISOL [J].
GOSLING, JP ;
MIDDLE, J ;
SIEKMANN, L ;
READ, G .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1993, 53 :3-41
[4]   THE AUTOMATION OF IMMUN-FIA-SYSTEMS [J].
HITZMANN, B ;
LOHN, A ;
REINECKE, M ;
SCHULZE, B ;
SCHEPER, T .
ANALYTICA CHIMICA ACTA, 1995, 313 (1-2) :55-62
[5]  
HUANG CM, 1989, CLIN CHEM, V35, P125
[6]  
KAPTEIN WA, 1997, IN PRESS BIOSENS BIO
[7]   Competitive flow injection enzyme immunoassay for steroids using a post-column reaction technique [J].
Kronkvist, K ;
Lovgren, U ;
Svenson, J ;
Edholm, LE ;
Johansson, G .
JOURNAL OF IMMUNOLOGICAL METHODS, 1997, 200 (1-2) :145-153
[8]   A CONTINUOUS-FLOW IMMUNOASSAY FOR RAPID AND SENSITIVE DETECTION OF SMALL MOLECULES [J].
KUSTERBECK, AW ;
WEMHOFF, GA ;
CHARLES, PT ;
YEAGER, DA ;
BREDEHORST, R ;
VOGEL, CW ;
LIGLER, FS .
JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 135 (1-2) :191-197
[9]  
McNeil C J, 1997, EXS, V81, P17
[10]   Ultrafiltrate sampling device for continuous monitoring [J].
Moscone, D ;
Venema, K ;
Korf, J .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (04) :290-294