Odour emission inventory of German wastewater treatment plants - odour flow rates and odour emission capacity

被引:38
作者
Frechen, FB [1 ]
机构
[1] Univ Kassel, Dept Sanitary & Environm Engn, D-34125 Kassel, Germany
关键词
odour emission capacity; odour flow rate; odour measurement; sewerage system; wastewater treatment plant;
D O I
10.2166/wst.2004.0244
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Wastewater Treatment plants can cause odour emissions that may lead to significant odour annoyance in their vicinity. Thus, over the past 20 years, several measurements were taken of the odour emissions that occur at WWTPs of different sizes, treatment technology, plant design and under different operating conditions. The specific aspects of odour sampling and measurement have to be considered. 1 presented some of the results of my odour emission measurements 11 years ago. However, it is now necessary to update the figures by evaluating newer measurement results obtained from measurements taken from 1994 to 2003. These are presented in this paper. Also, the paper highlights the odour emission capacity (OEC) measurement technique which characterises liquids and can be used to assess the results achieved by different types of treatment in the liquid phase, e.g. in a sewerage system. In addition, the OEC is a suitable parameter to set standards for the odorant content of industrial wastewaters that are discharged into the publicly owned sewerage system.
引用
收藏
页码:139 / 146
页数:8
相关论文
共 9 条
[1]  
*EUR STAND, 2003, EN137252003 EUR STAN
[2]  
Frechen F.-B., 2001, ODOURS WASTEWATER TR
[3]   Odour emission capacity of wastewaters - Standardization of measurement method and application [J].
Frechen, FB ;
Koster, W .
WATER SCIENCE AND TECHNOLOGY, 1998, 38 (03) :61-69
[4]   Aerodynamic performance of a low-speed wind tunnel [J].
Frechen, FB ;
Frey, M ;
Wett, M ;
Löser, C .
WATER SCIENCE AND TECHNOLOGY, 2004, 50 (04) :57-64
[6]   Odour measurement and odour policy in Germany [J].
Frechen, FB .
WATER SCIENCE AND TECHNOLOGY, 2000, 41 (06) :17-24
[7]  
*VDI, 1992, VDI HDB AIR POLL PRE, V1
[8]  
*VDI, 1994, VDI HDB AIR POLL PRE, V1
[9]  
*VDI, 1986, VDI HDB AIR POLL PRE, V1