Measurement of absolute light yield and determination of a lower limit for the light attenuation length for YAP:Ce crystal

被引:17
作者
Del guerra, A
de Notaristefani, F
Di Domenico, G
Zavattini, G
机构
[1] Ist Nazl Fis Nucl, I-44100 Ferrara, Italy
[2] Univ La Sapienza, Dipartimento Med Sperimentale, Rome, Italy
[3] Ist Nazl Fis Nucl, Rome, Italy
[4] Univ Roma 3, Dipartimento Fis, Rome, Italy
关键词
D O I
10.1109/23.656445
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In small animal PET applications YAP:Ce scintillator has given some promising results [1]. Because of its somewhat lower efficiency with respect to other PET crystals at 511 keV the depth of the crystal is a crucial parameter Past measurements of the light attenuation length for YAP:Ce scintillator have given rather different results with values as low as 3 cm [2]. We have Studied the pulse height spectra of full energy absorption events as a function of the interaction distance from the photomultiplier window for five match like 2 x 2 x 30 mm(3) YAP:Ce crystals. Each crystal was covered on the four long sides and on one of the square section sides with a 5 mu m reflective layer. The crystals were the middle row of a bundle of 5 by 5 such crystals. By using a transport model for-light within the crystals, for this crystal configuration, we obtained a lower limit of 6.8 +/- 0.3 cm on the average 'bulk' (not including the losses from reflection) light attenuation length. This lower limit is significantly higher than the attenuation length measured by other authors. From these measurements and calculations we have also determined the average absolute light yield for the five crystals to be 24000 +/- 1100 photons/MeV.
引用
收藏
页码:2415 / 2418
页数:4
相关论文
共 11 条
[1]   YALO3 - CE-FAST-ACTING SCINTILLATORS FOR DETECTION OF IONIZING-RADIATION [J].
BARYSHEVSKY, VG ;
KORZHIK, MV ;
MOROZ, VI ;
PAVLENKO, VB ;
FYODOROV, AA ;
SMIRNOVA, SA ;
EGORYCHEVA, OA ;
KACHANOV, VA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 58 (02) :291-293
[2]   THE OPTIMIZATION OF SMALL CSI(TL) GAMMA-RAY DETECTORS [J].
BIRD, AJ ;
CARTER, T ;
DEAN, AJ ;
RAMSDEN, D ;
SWINYARD, BM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :395-399
[4]   THEORETICAL MODELING OF LIGHT TRANSPORT IN RECTANGULAR PARALLELEPIPEDIC SCINTILLATORS [J].
CARRIER, C ;
LECOMTE, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 292 (03) :685-692
[5]   COLLECTION OF SCINTILLATION LIGHT FROM SMALL BGO CRYSTALS [J].
CHERRY, SR ;
SHAO, YP ;
TORNAI, MP ;
SIEGEL, S ;
RICCI, AR ;
PHELPS, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1058-1063
[6]  
DELGUERRAA, 1996, IEEE T NUCL SCI, V43, P1958
[7]  
*HAMAMATSU, 1989, HAMAMATSU TECHN DAT
[8]   DESIGN STUDIES FOR A PET DETECTOR MODULE USING A PIN PHOTODIODE TO MEASURE DEPTH OF INTERACTION [J].
MOSES, WW ;
DERENZO, SE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1441-1445
[9]  
WEBER MJ, 1969, APPL PHYS LETT, V15, P3442
[10]   CHARACTERISTICS OF THE NEW YALO(3) - CE COMPARED WITH BGO AND GSO [J].
ZIEGLER, SI ;
ROGERS, JG ;
SELIVANOV, V ;
SINITZIN, I .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (02) :194-197