Minimally invasive close-chest method for creating reperfused or occlusive myocardial infarction in swine

被引:20
作者
Krombach, GA
Kinzel, S
Mahnken, AH
Günther, RW
Buecker, A
机构
[1] Univ Technol Aachen, Univ Hosp, Dept Diagnost Radiol, D-52057 Aachen, Germany
[2] Univ Technol Aachen, Univ Hosp, Dept Lab Anim Sci, D-52057 Aachen, Germany
关键词
coronary artery occlusion; myocardial infarction; coronary artery catheterization;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: We sought to evaluate a closed-chest model for reperfused and occlusive myocardial infarction (MI) in pigs and to report experiences and pitfalls. Material and Methods: In 44 pigs, a balloon catheter was advanced into the left descending coronary artery (LAD) under fluoroscopic guidance. The balloon was inflated and occlusion of the vessel angiographically confirmed while ECG was continuously monitored. In case of ventricular fibrillation, direct current defibrillation was performed. In 6 animals, the balloon was left inflated during the following experiments, to obtain occlusive MI. In all other cases, the balloon was deflated after 45 minutes. After the experiments were finished, the hearts were stained with 2,3,5-triphenyltetrazolium chloride for assessment of infarct size. Results: MI was successfully induced in 34 animals (28 reperfused and 6 occlusive). Mean size of MI was 15.8 +/- 5.1% of left ventricular surface area for reperfused and 21.5 +/- 8.7% for occlusive infarcts. In one pig, 2,3,5-triphenyltetrazolium chloride did not confirm infarction. In 26 pigs, ventricular fibrillation occurred. Defibrillation was successful in 17 pigs. Failure rate because of ventricular fibrillation decreased from 42% (6) in the first 14 to 10% (3) in the next 30 animals. One animal died due to technical failure of the ventilator. After initial experiences, we used balloon catheters with a diameter of 2-3 mm, instead of 4 mm. The smaller balloon sizes were used so as to decrease the incidence of fibrillation. Conclusions: The described technique of LAD occlusion presents a less invasive alternative to open chest models. The major pitfall, causing fatal arrhythmia in our series, was over-dilatation of the LAD with the balloon catheter.
引用
收藏
页码:14 / 18
页数:5
相关论文
共 19 条
[1]   In and ex vivo MR evaluation of acute myocardial ischemia in pigs by determining R1 in steady state after the administration of the intravascular contrast agent NC100150 injection [J].
Bjerner, T ;
Johansson, L ;
Wikström, G ;
Ericsson, A ;
Briley-Saebo, K ;
Bjornerud, A ;
Ahlström, H .
INVESTIGATIVE RADIOLOGY, 2004, 39 (08) :479-486
[2]   High in-plane resolution T2-weighted magnetic resonance Imaging of acute myocardial ischemia in pigs using the intravascular contrast agent NC100150 injection [J].
Bjerner, T ;
Wikström, G ;
Johansson, L ;
Ahlström, H .
INVESTIGATIVE RADIOLOGY, 2004, 39 (08) :470-478
[3]  
CERRA F B, 1973, Review of Surgery, V30, P445
[4]   A model of closed chest regional myocardial infarction in the rabbit:: a clinically relevant in vivo assay system of post-infarction remodelling [J].
Edwards, R ;
Yousef, Z ;
Rakhit, R ;
Wright, M ;
Rosenthal, E ;
Redwood, S ;
Marber, M .
BASIC RESEARCH IN CARDIOLOGY, 2002, 97 (05) :374-383
[5]  
FOZZARD HA, 1975, CIRCULATION, V52
[6]   Relation between Gd-DTPA contrast enhancement and regional inotropic response in the periphery and center of myocardial infarction [J].
Gerber, BL ;
Rochitte, CE ;
Bluemke, DA ;
Melin, JA ;
Crosille, P ;
Becker, LC ;
Lima, JAC .
CIRCULATION, 2001, 104 (09) :998-1004
[7]   Acute myocardial infarction: Contrast-enhanced multi-detector row CT in a porcine model [J].
Hoffman, U ;
Millea, R ;
Enzweiler, C ;
Ferencik, M ;
Gulick, S ;
Titus, J ;
Achenbach, S ;
Kwait, D ;
Sosnovik, D ;
Brady, TJ .
RADIOLOGY, 2004, 231 (03) :697-701
[8]   Myocardial Gd-DTPA kinetics determine MRI contrast enhancement and reflect the extent and severity of myocardial injury after acute reperfused infarction [J].
Kim, RJ ;
Chen, EL ;
Lima, JAC ;
Judd, RM .
CIRCULATION, 1996, 94 (12) :3318-3326
[9]   Minimally invasive method for creating coronary stenosis in a swine model for MRI and SPECT imaging [J].
Kraitchman, DL ;
Bluemke, DA ;
Chin, BB ;
Heldman, AW ;
Heldman, AW .
INVESTIGATIVE RADIOLOGY, 2000, 35 (07) :445-451
[10]   Ultrasmall superparamagnetic particles of iron oxide (USPIO) MR imaging of infarcted myocardium in pigs [J].
Kroft, LJM ;
Doornbos, J ;
van der Geest, RJ ;
van der Laarse, A ;
van der Meulen, H ;
de Rosa, A .
MAGNETIC RESONANCE IMAGING, 1998, 16 (07) :755-763