Clinical use of WHO haemoglobin colour scale: validation and critique

被引:39
作者
Ingram, CF
Lewis, SM [1 ]
机构
[1] Hammersmith Hosp, Imperial Coll Sch Med, Dept Haematol, WHO Collaborating Ctr Haematol Technol, London W12 0NN, England
[2] S African Inst Med Res, Helen Joseph Hosp Lab, ZA-2000 Johannesburg, South Africa
关键词
diagnosis of anaemia; haemoglobinometry; haemoglobin colour scale; clinical assessment of anaemia;
D O I
10.1136/jcp.53.12.933
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Aim-The World Health Organisation (WHO) haemoglobin colour scale has been developed as a simple, inexpensive clinical device for diagnosing anaemia when laboratory based haemoglobinometry is not available. In an initial validation study at several health centres, scale readings were compared with measurements of haemoglobin by the laboratory. This showed the scale to have 90% sensitivity and 70% specificity in identifying whether anaemia was present or not. In addition, when present, the degree of anaemia was correctly classified in clinical terms as moderate, pronounced, or severe, with an overall sensitivity of 60% and specificity of 88%. Errors were mainly marginal-that is, between two adjacent categories-but there were also some major discrepancies, such as a blood with a haemoglobin of 6-7 g/dl being read as normal or vice versa. Because this would compromise the scale's reliability in practice, this study was undertaken to identify the causes of the discrepancies and to reassess the performance of the scale. Methods-Venous blood samples were collected into potassium EDTA from patients attending selected clinics at three South African hospitals with good laboratory facilities. A prototype of the device was used unsupervised by nursing staff, doctors, and phlebotomists, who were told to follow the printed instructions. The blocked specimens were then immediately sent to the laboratory where haemoglobin was measured by standardised automated blood cell counters. Any discrepancies > 1 g/dl were recorded and the tests were repeated by the same operators under supervision of the investigators. Results-Almost all the errors that occurred resulted from the incorrect use of the device, namely: inadequate or excessive blood, reading the results too soon or too late (beyond the limit of two minutes), poor lighting, or holding the scale at the wrong angle. The accuracy improved dramatically when the tests were repeated under supervision and these faults were avoided: 95% of readings were within 1 g/dl of the reference measurements, and 97% within 1.5 g/dl. Anaemia screening showed 96% sensitivity and 86% specificity. Clinical judgement of pallor was frequently wrong, whereas the scale gave the correct diagnosis in more than 97% of cases. Conclusion-The study confirmed the usefulness and reliability of the scale and its advantage over clinical signs for the diagnosis of anaemia, thus providing a clinically reliable near patient method in the absence of a laboratory. The instructions are easy to follow but must be strictly adhered to.
引用
收藏
页码:933 / 937
页数:5
相关论文
共 11 条
[1]  
Beales PF, 1997, ANN TROP MED PARASIT, V91, P713, DOI 10.1080/00034989760446
[2]  
Galen RS, 1975, NORMALITY PREDICTIVE
[3]   Training health workers to assess anaemia with the WHO haemoglobin colour scale [J].
Gosling, R ;
Walraven, G ;
Manneh, F ;
Bailey, B ;
Lewis, SM .
TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2000, 5 (03) :214-221
[4]  
International Committee for Standardization in Haematology, 1987, CLIN LAB HAEMATOL, V9, P73
[5]   An inexpensive and reliable new haemoglobin colour scale for assessing anaemia [J].
Lewis, SM ;
Stott, GJ ;
Wynn, KJ .
JOURNAL OF CLINICAL PATHOLOGY, 1998, 51 (01) :21-24
[6]   Field trial of a haemoglobin colour scale: an effective tool to detect anaemia in preschool children [J].
Montresor, A ;
Albonico, M ;
Khalfan, N ;
Stoltzfus, RJ ;
Tielsch, JM ;
Chwaya, HM ;
Savioli, L .
TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2000, 5 (02) :129-133
[7]  
Münster M, 1997, S AFR MED J, V87, P1522
[8]  
STOTT GJ, 1995, B WORLD HEALTH ORGAN, V73, P369
[9]  
van den Broek NR, 1999, B WORLD HEALTH ORGAN, V77, P15
[10]  
YOUDEN WJ, 1950, BIOMETRICS, V6, P172, DOI 10.1002/1097-0142(1950)3:1<32::AID-CNCR2820030106>3.0.CO