Captopril renography and duplex Doppler sonography in the diagnosis of renovascular hypertension

被引:26
作者
Kaplan-Pavlovcic, S [1 ]
Nadja, C [1 ]
机构
[1] Univ Ljubljana, Med Ctr, Dept Nephrol, Ljubljana 1525, Slovenia
关键词
captopril renal scintigraphy; duplex Doppler sonography; renovascular hypertension;
D O I
10.1093/oxfordjournals.ndt.a027824
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. The purpose of this prospective study was to determine the clinical usefulness of captopril renal scintigraphy and duplex Doppler sonography in detecting haemodynamically significant renal artery stenosis (greater than or equal to 60%) and predicting cure or improvement of hypertension following revascularisation. Methods. Twenty-eight patients with moderate or high index of clinical suspicion of renovascular hypertension underwent both captopril renal scintigraphy and duplex Doppler sonography before undergoing renal angiography. Patients with angiographically proved (greater than or equal to 60%) RAS were treated by percutaneous transluminal renal angioplasty unless it was contraindicated. Results. The results of captopril renal scintigraphy and duplex Doppler sonography were compared by renal angiography of 45 renal arteries in 28 patients. Eleven renal arteries were excluded from further comparison, because no accurate Doppler signal could be obtained. The sensitivity and specificity of captopril renal scintigraphy in the identification of RAS (greater than or equal to 60%) was 78% and 81% respectively. The sensitivity of duplex Doppler sonography was 83% and the specificity was 81%. Positive predictive values of both tests for blood pressure cure or improvement after PTRA were 86% for CRS and 85% for DDS. Conclusions. Captopril renal scintigraphy and duplex Doppler sonography are comparable tests for detection of patients with haemodynamically significant renal artery stenosis (greater than or equal to 60%). Positive predictive values of both tests for cure or improvement of hypertension after percutaneous transluminal renal angioplasty are good and comparable.
引用
收藏
页码:313 / 317
页数:5
相关论文
共 23 条
[1]   UNILATERAL RENAL-ARTERY STENOSIS AND HYPERTENSION .1. ANGIOGRAPHY [J].
ANDERSSON, I .
ACTA RADIOLOGICA-DIAGNOSIS, 1979, 20 (06) :878-894
[2]  
Dondi M, 1992, J Nucl Biol Med, V36, P309
[3]   CAPTOPRIL RENAL SCINTIGRAPHY WITH TC-99M-MERCAPTOACETYLTRIGLYCINE (TC-99M-MAG3) FOR DETECTING RENAL-ARTERY STENOSIS [J].
DONDI, M .
AMERICAN JOURNAL OF HYPERTENSION, 1991, 4 (12) :S737-S740
[4]   EUROPEAN CAPTOPRIL RADIONUCLIDE TEST MULTICENTER STUDY - PRELIMINARY-RESULTS - INSPECTIVE RENOGRAPHIC ANALYSIS [J].
FOMMEI, E ;
MEZZASALMA, L ;
GHIONE, S ;
VOLTERRANI, D ;
OEI, Y ;
HILSON, AJW ;
CARRIERI, M ;
BAUM, RP ;
BEUERLEIN, I ;
BRIANZONI, E ;
DONDI, M ;
DUPONT, A ;
FRAILE, M ;
GRANJON, D ;
GOGGIN, MJ ;
HOSCHL, R ;
JENSEN, G ;
JEZERSEK, P ;
LANSIMIES, E ;
MULLERSUUR, R ;
VANMONTFRANS, GA ;
PIEPSZ, A ;
POROPAT, M ;
PROUKAKIS, C ;
SANTOS, CG ;
SEREFOGLOU, A ;
WAUTRECHT, JC .
AMERICAN JOURNAL OF HYPERTENSION, 1991, 4 (12) :S690-S697
[5]   TECHNIQUE OF PERCUTANEOUS TRANS-LUMINAL ANGIOPLASTY WITH THE GRUNTZIG BALLOON CATHETER [J].
GRUNTZIG, A ;
KUMPE, DA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1979, 132 (04) :547-552
[6]  
HAIMOVICI H, 1962, J CARDIOVASC SURG, V3, P259
[7]   ROLE OF DUPLEX SCANNING FOR THE DETECTION OF ATHEROSCLEROTIC RENAL-ARTERY DISEASE [J].
HOFFMANN, U ;
EDWARDS, JM ;
CARTER, S ;
GOLDMAN, ML ;
HARLEY, JD ;
ZACCARDI, MJ ;
STRANDNESS, DE .
KIDNEY INTERNATIONAL, 1991, 39 (06) :1232-1239
[8]   RENAL ARTERY STENOSIS - CLINICAL-PATHOLOGIC STUDY IN NORMOTENSIVE + HYPERTENSIVE PATIENTS [J].
HOLLEY, KE ;
KINCAID, OW ;
BROWN, AL ;
SHEPS, SG ;
HUNT, JC .
AMERICAN JOURNAL OF MEDICINE, 1964, 37 (01) :14-&
[9]   ISCHEMIC RENAL-DISEASE - AN OVERLOOKED CLINICAL ENTITY [J].
JACOBSON, HR ;
KURTIN, P ;
HARRINGTON, JT ;
MADAIO, M ;
MADIAS, NE ;
MILLAN, VG ;
KOPELMAN, R .
KIDNEY INTERNATIONAL, 1988, 34 (05) :729-743
[10]  
JONKER GJ, 1993, NEPHROL DIAL TRANSPL, V8, P798