Five-repetition sit-to-stand test performance by community-dwelling adults: A preliminary investigation of times, determinants, and relationship with self-reported physical performance

被引:89
作者
Bohannon, Richard W. [1 ]
Shove, Megan E.
Barreca, Susan R.
Masters, Lisa M.
Sigouin, Christopher S.
机构
[1] Univ Connecticut, Dept Phys Therapy, Storrs, CT 06269 USA
[2] McMaster Univ, Sch Rehabil Sci, Hamilton, ON, Canada
[3] Univ Toronto, Dept Hlth Policy, Toronto, ON, Canada
[4] Hamilton Hlth Sci, Orthoped & Rehabil Serv, Hamilton, ON, Canada
关键词
muscle; strength; screening test; reliability; validity;
D O I
10.3233/IES-2007-0253
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The 5-repetition sit-to-stand (STS) test is a widely used, but insufficiently evaluated, test for lower limb strength. We therefore described STS test times for a sample of community-dwelling adults, examined the association of age, gender, height, weight, and body mass index (BMI) with STS time, and determined the relationship of STS time with self-reported physical functioning. Ninety-four community dwelling adults participated. Repeated measures of STS time were reliable (intraclass correlation coefficient = 0.957). The mean STS time for all 94 subjects was 7.6 seconds. Age, weight, and BMI were (r = 0.281-0.528), but gender and height were not (r = -0.074 - 0.007), correlated significantly with STS time. Regression analysis showed that age and BMI explained 43.7 percent of the variance in STS time. The correlation between STS time and physical functioning (r = -0.474) was significant (p < 0.001). Regression analysis showed that age and BMI added slightly to the explanation of variance in physical functioning provided by STS time. In conclusion, this study provides STS times that might be useful for interpreting performance of adults screened with the test. Such performance should be considered in light of age and BMI. The relationship of STS time with physical functioning provides evidence of the validity of the measure.
引用
收藏
页码:77 / 81
页数:5
相关论文
共 12 条
[1]  
Bohannon Richard W, 2005, J Geriatr Phys Ther, V28, P10
[2]   Reference values for the five-repetition sit-to-stand test: A descriptive meta-analysis of data from elders [J].
Bohannon, Richard W. .
PERCEPTUAL AND MOTOR SKILLS, 2006, 103 (01) :215-222
[3]  
Bohannon RW, 2005, TOP GERIATR REHABIL, V21, P350
[4]   Alternatives for measuring knee extension strength of the elderly at home [J].
Bohannon, RW .
CLINICAL REHABILITATION, 1998, 12 (05) :434-440
[5]   DEFICITS IN LOWER-EXTREMITY MUSCLE AND GAIT PERFORMANCE AMONG RENAL-TRANSPLANT CANDIDATES [J].
BOHANNON, RW ;
SMITH, J ;
HULL, D ;
PALMERI, D ;
BARNHARD, R .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1995, 76 (06) :547-551
[6]   SIT-TO-STAND TEST FOR MEASURING PERFORMANCE OF LOWER-EXTREMITY MUSCLES [J].
BOHANNON, RW .
PERCEPTUAL AND MOTOR SKILLS, 1995, 80 (01) :163-166
[7]   SIMPLE METHOD FOR MEASUREMENT OF LOWER-EXTREMITY MUSCLE STRENGTH [J].
CSUKA, M ;
MCCARTY, DJ .
AMERICAN JOURNAL OF MEDICINE, 1985, 78 (01) :77-81
[8]  
Massey B, 2001, PHYS THER, V81, P9
[9]   'The multiple-sit-to-stand' field test for older adults: What does it measure? [J].
Netz, Y ;
Ayalon, M ;
Dunsky, A ;
Alexander, N .
GERONTOLOGY, 2004, 50 (03) :121-126
[10]   Development and validation of a functional fitness test for community-residing older adults [J].
Rikli, RE ;
Jones, CJ .
JOURNAL OF AGING AND PHYSICAL ACTIVITY, 1999, 7 (02) :129-161