Effect of oxygen ashing on analyte transport efficiency using ETV-ICP-MS

被引:30
作者
Fonseca, RW
Miller-Ihli, NJ [1 ]
Sparks, C
Holcombe, JA
Shaver, B
机构
[1] ARS, USDA, Beltsville Human Nutr Res Ctr, Food Composit Lab, Beltsville, MD 20705 USA
[2] Univ Texas, Dept Chem & Biochem, Austin, TX 78712 USA
[3] SEMATECH, Austin, TX 78712 USA
关键词
electrothermal vaporization; inductively coupled plasma mass spectrometry; oxygen ashing; catalytic carbon oxidation; analyte transport; direct solids analysis; ultrasonic slurry sampling; physical carrier; palladium;
D O I
10.1366/0003702971939866
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Oxygen ashing has been used in electrothermal atomic absorption spectroscopy to eliminate organic matrix sample components and is particularly useful when doing direct solids analysis of biologicals using ultrasonic slurry sampling, Oxygen ashing has also proven to be useful for the analysis of slurry samples using ultrasonic slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry (USS-ETV-ICP-MS). In this work, the effect of oxygen ashing on analyte transport in USS-ETV-ICP-MS was evaluated, Oxygen ashing in the presence of Pd modifier (Pd/O-2) enhances analyte transport efficiency, possibly as a result of an increase in the number of carbon particles present in the graphite furnace during the vaporization step, These carbon particles act as a physical carrier, providing a surface on which the analytes can condense to be transported more efficiently, The carbon produced at earlier times, with Pd/O-2, may be the result of either dissociation or fracture of the graphite during the rapid heating of the furnace, Pd, which was initially added to act as a physical carrier, also seems to be acting as a catalyst for carbon oxidation, The shift in the carbon signal toward earlier times when using oxygen ashing was observed only when Pd was present, In addition, scanning electron micrographs of a home-made graphite platform revealed that portions of the graphite substrate were missing when Pd/O-2 was used and that clearly visible pits were found in the graphite. Oxygen ashing combined with 1 mu g Pd improves quantitative results by removing the organic part of the matrix present in slurry samples while enhancing analyte transport efficiency by providing carbon particles that serve as a physical carrier.
引用
收藏
页码:1800 / 1806
页数:7
相关论文
共 26 条
[1]   CATALYTIC GASIFICATION OF GRAPHITE BY CHROMIUM AND COPPER IN OXYGEN, STEAM AND HYDROGEN [J].
BAKER, RTK ;
CHLUDZINSKI, JJ .
CARBON, 1981, 19 (02) :75-82
[2]   SOLID SAMPLING IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY USING COMMERCIAL ATOMIZERS - A REVIEW [J].
BENDICHO, C ;
DELOOSVOLLEBREGT, MTC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (05) :353-374
[3]  
BERES S, 1994, SPECTROSCOPY, V9, P20
[4]   OXYGEN ASHING AND MATRIX MODIFIERS IN GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRIC DETERMINATION OF LEAD IN WHOLE-BLOOD [J].
EATON, DK ;
HOLCOMBE, JA .
ANALYTICAL CHEMISTRY, 1983, 55 (06) :946-950
[5]   OXYGEN ASHING ATTACHMENT FOR A FURNACE ATOMIZER POWER-SUPPLY [J].
EATON, DK ;
HOLCOMBE, JA .
ANALYTICAL CHEMISTRY, 1983, 55 (11) :1821-1823
[6]   THE ROLE OF CHEMICAL MODIFIERS IN ANALYTE TRANSPORT LOSS INTERFERENCES WITH ELECTROTHERMAL VAPORIZATION ICP-MASS SPECTROMETRY [J].
EDIGER, RD ;
BERES, SA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (07) :907-922
[7]   ANALYTE TRANSPORT STUDIES OF AQUEOUS-SOLUTIONS AND SLURRY SAMPLES USING ELECTROTHERMAL VAPORIZATION ICP-MS [J].
FONSECA, RW ;
MILLERIHLI, NJ .
APPLIED SPECTROSCOPY, 1995, 49 (10) :1403-1410
[8]   KINETICS OF RELEASE OF CARBON AND CARBON-MONOXIDE FROM A GRAPHITE-FURNACE INVESTIGATED BY ELECTROTHERMAL VAPORIZATION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
GILMUTDINOV, AK ;
STAROVEROV, AE ;
GREGOIRE, DC ;
STURGEON, RE ;
CHAKRABARTI, CL .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1994, 49 (10) :1007-1026
[9]   ELECTROTHERMAL VAPORIZATION FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY AND ATOMIC-ABSORPTION SPECTROMETRY - SYMBIOTIC ANALYTICAL TECHNIQUES [J].
GREGOIRE, DC ;
LAMOUREUX, M ;
CHAKRABARTI, CL ;
ALMAAWALI, S ;
BYRNE, JP .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (04) :579-585
[10]   DIRECT ANALYSIS OF SOLIDS BY ULTRASONIC SLURRY ELECTROTHERMAL VAPORIZATION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
GREGOIRE, DC ;
MILLERIHLI, NJ ;
STURGEON, RE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (05) :605-610