Continuous peripheral nerve blocks with stimulating catheters

被引:71
作者
Pham-Dang, C [1 ]
Kick, O [1 ]
Collet, T [1 ]
Gouin, F [1 ]
Pinaud, M [1 ]
机构
[1] Univ Hosp Nantes, Hotel Dieu, Nantes, France
关键词
catheter; continuous; block; neurostimulation;
D O I
10.1053/rapm.2003.50005
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Objectives: This study evaluated the efficacy of stimulating catheters used for continuous peripheral nerve blocks as a means of immediate verification and confirmation of correct catheter position. Methods: This observational study presents our experience with 130 stimulating catheters used in 40 intersternocleidomastoid, 24 axillary, 47 femoral, and 19 lateral midfemoral sciatic nerve blocks. Placement characteristics (amperage, depth of introducer needle or catheter insertion, elicited motor responses), subsequent postoperative analgesia, and catheter position evaluated with the radiopaque dye analysis were all studied. Results: Except in femoral blocks, characteristics of motor responses elicited (1 Hz, 0,1 ms) by the introducer assembly and catheter differed. The amperage required to elicit motor responses typically was higher with the catheter than with the introducer needle (1.6 [0.2 to 4 mA] v 0.5 [0.4 to 1 mA] P < .0001). The ability to elicit a motor response with the stimulating catheter correlated with successful clinical anesthesia in 124 cases. Opacified radiography showed no aberrant position in these cases. Three catheters for upper limb block failed to stimulate, provided poor anesthesia, and had radiologic evidence of aberrant position. Even though they failed to stimulate, 3 catheters for sciatic block functioned well, and the opacified radiography showed correct position. Conclusion: The ability to electrostimulate nerves using an in situ catheter increases success rate in catheter placement for continuous peripheral nerve blocks. Further controlled investigations are necessary to compare this technique with more conventional methods in terms of cost and utility for various peripheral nerve blocks. Reg Anesth Pain Med 2003,-28.83-88.
引用
收藏
页码:83 / 88
页数:6
相关论文
共 15 条
[1]  
ANG ET, 1984, ANESTH ANALG, V63, P680
[2]  
Bannister LH, 1995, GRAYS ANATOMY, P1277
[3]   Continuous three-in-one block for postoperative pain after lower limb orthopedic surgery: Where do the catheters go? [J].
Capdevila, X ;
Biboulet, P ;
Morau, D ;
Bernard, N ;
Deschodt, J ;
Lopez, S ;
d'Athis, F .
ANESTHESIA AND ANALGESIA, 2002, 94 (04) :1001-1006
[4]   Comparison of the three-in-one and fascia iliaca compartment blocks in adults: Clinical and radiographic analysis [J].
Capdevila, X ;
Biboulet, P ;
Bouregba, M ;
Barthelet, Y ;
Rubenovitch, J ;
d'Athis, F .
ANESTHESIA AND ANALGESIA, 1998, 86 (05) :1039-1044
[5]   A new stimulating catheter for continuous peripheral nerve blocks [J].
Copeland, SJ ;
Laxton, MA .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2001, 26 (06) :589-590
[6]   Midfemoral block: A new lateral approach to the sciatic nerve [J].
Dang, CP .
ANESTHESIA AND ANALGESIA, 1999, 88 (06) :1426-1426
[7]  
DANG CP, 2001, ANESTHESIOLOGY, V95, pA943
[8]  
FORD DJ, 1984, ANESTH ANALG, V63, P925
[9]   Modified continuous femoral three-in-one block for postoperative pain after total knee arthroplasty [J].
Ganapathy, S ;
Wasserman, RA ;
Watson, JT ;
Bennett, J ;
Armstrong, KP ;
Stockall, CA ;
Chess, DG ;
MacDonald, C .
ANESTHESIA AND ANALGESIA, 1999, 89 (05) :1197-1202
[10]   2 APPROACHES TO THE AXILLARY BRACHIAL-PLEXUS - LOSS OF RESISTANCE TO SALINE OR PARESTHESIA [J].
HILL, DA ;
CAMPBELL, WI .
ANAESTHESIA, 1992, 47 (03) :207-209