A physiologically based clinical measure for spastic reflexes in spinal cord injury

被引:103
作者
Benz, EN
Hornby, TG
Bode, RK
Scheidt, RA
Schmit, BA
机构
[1] Marquette Univ, Dept Biomed Engn, Milwaukee, WI 53201 USA
[2] Rehabil Inst Chicago, Senory Motor Performance Program, Chicago, IL 60611 USA
[3] Rehabil Inst Chicago, Ctr Rehabil Outcomes Res, Chicago, IL 60611 USA
[4] Northwestern Univ, Dept Phys Med & Rehabil, Chicago, IL 60611 USA
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2005年 / 86卷 / 01期
关键词
muscle hypertonia; muscle spasticity; rehabilitation; spinal cord injuries;
D O I
10.1016/j.apmr.2004.01.033
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To test the validity of the Spinal Cord Assessment Tool for Spastic reflexes (SCATS), a clinical tool intended to rate spastic motor behavior after spinal cord injury (SCI). Design: By using correlational analyses, the SCATS was validated using concurrent measurements of kinematics and electromyograms and traditional assessments of spasms and spastic hypertonia. Setting: Research laboratory (kinematics and electromyography) and outpatient medical clinic (traditional measures of spastic hypertonia). Participants: Eleven people with SCI were used for kinematic and electromyographic measurements. Seventeen people with SCI were used for comparison with other clinical scales. Interventions: Not applicable. Main Outcome Measures: Kinematic and surface electromyographic measurements of the tested lower extremity were used to quantify magnitude and/or duration of motor behaviors, and the Penn Spasm Frequency Scale (PSFS) and the Ashworth Scale were used to measure spasm frequency and resistance to joint movement for the hip flexors, knee flexors, and ankle plantarflexors, respectively. Concurrently, the SCATS was used to assess the clonus response to an imposed ankle dorsiflexion, the flexion response to a stimulus to the foot, and the knee extensor activity in response to an imposed lea extension. Each component of the SCATS was compared with the Ashworth Scale, the PSFS, and kinematic and electromyographic measurements by using the Spearman rank correlation test. Results: Clonus, flexor spasm, and extensor spasm responses measured by using the SCATS correlated significantly with kinematic and electromyographic recordings (P<.01). Significant correlations were also observed between the S CATS extensor spasms and the Ashworth scores for hip and knee flexors and for ankle plantarflexors (rho=.98, .88, .61, respectively). Also, SCATS flexor spasms and SCATS clonus scores correlated significantly with some of the Ashworth scores. Only SCATS clonus scores correlated significantly with spasm frequency measures (rho=.59, P<.05). Conclusions: The SCATS produced a valid measure of 3 distinct types of spastic motor behaviors in SCI and may provide a complementary tool for measuring spastic hypertonia. Such a measure is valuable because current assessment tools do not differentiate between the different types of spastic motor behaviors that manifest after SCI. Distinguishing the 3 spastic reactions using an efficient and valid clinical tool may help guide management of spastic hypertonia in SCI.
引用
收藏
页码:52 / 59
页数:8
相关论文
共 28 条
[1]  
[Anonymous], SPASTICITY DISORDERE
[2]  
ASHWORTH B, 1964, PRACTITIONER, V192, P540
[3]   Reliability of measurements obtained with the Modified Ashworth Scale in the lower extremities of people with stroke [J].
Blackburn, M ;
van Vliet, P ;
Mockett, SP .
PHYSICAL THERAPY, 2002, 82 (01) :25-34
[4]   INTERRATER RELIABILITY OF A MODIFIED ASHWORTH SCALE OF MUSCLE SPASTICITY [J].
BOHANNON, RW ;
SMITH, MB .
PHYSICAL THERAPY, 1987, 67 (02) :206-207
[5]   PHYSIOLOGICAL CLONUS IN MAN [J].
GOTTLIEB, GL ;
AGARWAL, GC .
EXPERIMENTAL NEUROLOGY, 1977, 54 (03) :616-621
[6]  
HECKMAN CJ, 1994, MED SCI SPORT EXER, V26, P1480
[7]  
Hidler J M, 1999, IEEE Trans Rehabil Eng, V7, P327, DOI 10.1109/86.788469
[8]  
Hinderer S R, 2001, Phys Med Rehabil Clin N Am, V12, P733
[9]   OBJECTIVE QUANTIFICATION OF SPASTIC HYPERTONIA - CORRELATION WITH CLINICAL FINDINGS [J].
KATZ, RT ;
ROVAI, GP ;
BRAIT, C ;
RYMER, WZ .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1992, 73 (04) :339-347
[10]   FUNCTIONAL CAPACITY OF THE ISOLATED HUMAN SPINAL CORD [J].
KUHN, RA .
BRAIN, 1950, 73 (01) :1-51