Three-dimensional structure analysis by X-ray micro-computed tomography of macroporous alumina templated with expandable microspheres

被引:23
作者
Andersson, Linnea [1 ]
Jones, Anthony C. [2 ]
Knackstedt, Mark A. [2 ]
Bergstrom, Lennart [1 ]
机构
[1] Stockholm Univ, Dept Mat & Environm Chem, SE-10691 Stockholm, Sweden
[2] Australian Natl Univ, Res Sch Phys Sci & Engn, Dept Appl Math, Canberra, ACT 0200, Australia
基金
瑞典研究理事会;
关键词
Porosity; X-ray methods; Non-destructive evaluation; Al2O3; Expandable microspheres; TRANSPORT-PROPERTIES; IMAGE-ANALYSIS; BONE;
D O I
10.1016/j.jeurceramsoc.2010.05.003
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The three-dimensional (3D) structures of macroporous alumina, produced by a novel method that combines gel casting with expandable polymeric microspheres as a sacrificial templating material, have been characterised by X-ray micro-computed tomography (mu-CT). The grey-scale intensity tomogram data produced by the X-ray mu-CT was segmented into porous and solid phases and the individual pores were identified. We compared two-dimensional slices of the analysed data with the corresponding scanning electron microscopy images and showed that the structural features of the pores were well reproduced in the X-ray mu-CT images. 3D visualisations of the pore structure and the pore network were also shown. The open porosity obtained from X-ray mu-CT corresponded well with the porosity derived from mercury porosimetry for pores larger than the voxel dimension (3 mu m). The quantitative analysis also yielded information on the spatial variations in porosity and the number of connected neighbours of pores. The 3D data was used to relate the calculated permeability to the open porosity. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2547 / 2554
页数:8
相关论文
共 38 条
[1]   Ceramic diesel particulate filters [J].
Adler, J .
INTERNATIONAL JOURNAL OF APPLIED CERAMIC TECHNOLOGY, 2005, 2 (06) :429-439
[2]   Extraction of physically realistic pore network properties from three-dimensional synchrotron X-ray microtomography images of unconsolidated porous media systems [J].
Al-Raoush, RI ;
Willson, CS .
JOURNAL OF HYDROLOGY, 2005, 300 (1-4) :44-64
[3]   Gas-filled microspheres as an expandable sacrificial template for direct casting of complex-shaped macroporous ceramics [J].
Andersson, Linnea ;
Bergstrom, Lennart .
JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2008, 28 (15) :2815-2821
[4]   Virtual permeametry on microtomographic images [J].
Arns, CH ;
Knackstedt, MA ;
Pinczewski, WV ;
Martys, NS .
JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2004, 45 (1-2) :41-46
[5]   Accurate estimation of transport properties from microtomographic images [J].
Arns, CH ;
Knackstedt, MA ;
Pinczewski, WV ;
Lindquist, WB .
GEOPHYSICAL RESEARCH LETTERS, 2001, 28 (17) :3361-3364
[6]   X-ray tomography study of the cellular structure of extruded starches and its relations with expansion phenomenon and foam mechanical properties [J].
Babin, P. ;
Della Valle, G. ;
Dendievel, R. ;
Lourdin, D. ;
Salvo, L. .
CARBOHYDRATE POLYMERS, 2007, 68 (02) :329-340
[7]   Advances in synchrotron radiation microtomography [J].
Baruchel, Jos ;
Buffiere, Jean-Yves ;
Cloetens, Peter ;
Di Michiel, Marco ;
Ferrie, Emilie ;
Ludwig, Wolfgang ;
Maire, Eric ;
Salvo, Luc .
SCRIPTA MATERIALIA, 2006, 55 (01) :41-46
[8]   Image analysis of X-ray microtomograms of Pd-Ag/SiO2 xerogel catalysts supported on Al2O3 foams [J].
Blacher, S ;
Léonard, A ;
Heinrichs, B ;
Tcherkassova, N ;
Ferauche, F ;
Crine, M ;
Marchot, P ;
Loukine, E ;
Pirard, JP .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2004, 241 (1-3) :201-206
[9]  
Clarke A.R., 2002, MICROSCOPY TECHNIQUE
[10]   New algorithms in 3D image analysis and their application to the measurement of a spatialized pore size distribution in soils [J].
Delerue, JP ;
Perrier, E ;
Yu, ZY ;
Velde, B .
PHYSICS AND CHEMISTRY OF THE EARTH PART A-SOLID EARTH AND GEODESY, 1999, 24 (07) :639-644