Accuracy of cyclosporin measurements made in capillary blood samples obtained by skin puncture

被引:35
作者
Merton, G
Jones, K
Lee, M
Johnston, A
Holt, DW
机构
[1] St George Hosp, Sch Med, Analyt Unit, London, England
[2] St Bartholomews & Royal London Sch Med & Dent, London, England
关键词
cyclosporin; capillary blood; therapeutic drug monitoring; finger prick; radioimmunoassay;
D O I
10.1097/00007691-200010000-00015
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
international consensus guidelines suggest that cyclosporin should be measured in whole blood. In some instances it may be advantageous to collect capillary blood, by a finger or ear prick method. However, drug concentrations in skin-puncture blood mat. not necessarily correlate with those measured in venous blood. This study compared cyclosporin concentrations in blood collected from the fingertip or earlobe with blood collected by standard venipuncture. Patient preference for each of the blood collection methods was also assessed. Specimens were obtained from organ transplant patients receiving cyclosporin, using each of the three methods: venipuncture, finger prick. and earlobe prick. The samples were assayed using a specific radioimmunoassay and the results were compared. In the 102 sets of samples collected, the mean difference (+/-standard deviation) in cyclosporin concentration between finger prick and venipuncture and ear prick and venipuncture was 2.6% (+/-9.5%) and 2.7% (+/-12.1%), respectively, while the comparable median (IQR) differences were 1.9% (-3.4% to +6.6%) and -1.1% (-2.8% to +7.2%), respectively. A high degree of correlation was observed between finger prick and venipuncture or ear prick and venipuncture or ear prick and finger prick (r(2) > 0.86). Of the three methods of blood collection, finger prick was the patients' preferred method (P < 0.01). These data suggest that capillary blood collected by skin puncture is suitable for use in cyclosporin blood monitoring and acceptable to patients.
引用
收藏
页码:594 / 598
页数:5
相关论文
共 23 条
[1]   SAMPLING FOR ANALYZING BLOOD-GAS PRESSURES - CAPILLARY SAMPLING IS ROUTINE IN GERMANY [J].
BERNHARDT, A .
BRITISH MEDICAL JOURNAL, 1995, 310 (6986) :1072-1072
[2]  
BLUMENFELD TA, 1977, CLIN CHEM, V23, P1705
[3]  
COOK JD, 1990, CLIN CHEM, V36, P780
[4]   ARTERIAL VERSUS CAPILLARY SAMPLING FOR ANALYZING BLOOD-GAS PRESSURES [J].
DAR, K ;
WILLIAMS, T ;
AITKEN, R ;
WOODS, KL ;
FLETCHER, S .
BRITISH MEDICAL JOURNAL, 1995, 310 (6971) :24-25
[5]  
DAVID O, 1999, THER DRUG MONIT, V21, P435
[6]  
Faynor SM, 1998, CLIN CHEM, V44, P2220
[7]   Peak cyclosporine levels (Cmax) correlate with freedom from liver graft rejection -: Results of a prospective, randomized comparison of neoral and sandimmune for liver transplantation (NOF-8) [J].
Grant, D ;
Kneteman, N ;
Tchervenkov, J ;
Roy, A ;
Murphy, G ;
Tan, A ;
Hendricks, L ;
Guilbault, N ;
Levy, G .
TRANSPLANTATION, 1999, 67 (08) :1133-1137
[8]  
Hollis S, 1996, ANN CLIN BIOCHEM, V33, P1
[9]   CYCLOSPORINE-A - ANALYTICAL METHODOLOGY AND FACTORS AFFECTING THERAPEUTIC DRUG-MONITORING [J].
HOLT, DW ;
JOHNSTON, A .
THERAPEUTIC DRUG MONITORING, 1995, 17 (06) :625-630
[10]  
HOLT DW, 1994, TRANSPL P, V26, P2935