Intrauterine device and upper-genital-tract infection

被引:225
作者
Grimes, DA [1 ]
机构
[1] Family Hlth Int, Res Triangle Pk, NC 27709 USA
关键词
D O I
10.1016/S0140-6736(00)02699-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Concern about upper-genital-tract infection related to intrauterine devices (IUDs) limits their wider use. In this systematic review I summarise the evidence concerning IUD-associated infection and infertility. Choice of an inappropriate comparison group, overdiagnosis of salpingitis in IUD users, and Inability to control for the confounding effects of sexual behaviour have exaggerated the apparent risk. Women with symptomless gonorrhoea or chlamydial infection having an IUD inserted have a higher risk of salpingitis than do uninfected women having an IUD inserted; however, the risk appears similar to that of infected women not having an IUD inserted. A cohort study of HIV-positive women using a copper IUD suggests that there is no significant increase in the risk of complications or viral shedding. Similarly, fair evidence indicates no important effect of IUD use on tubal infertility. Contemporary IUDs rival tubal sterilisation in efficacy and are much safer than previously thought.
引用
收藏
页码:1013 / 1019
页数:7
相关论文
共 89 条
[1]   LEVONORGESTREL-RELEASING AND COPPER-RELEASING (NOVA T) IUDS DURING 5 YEARS OF USE - A RANDOMIZED COMPARATIVE TRIAL [J].
ANDERSSON, K ;
ODLIND, V ;
RYBO, G .
CONTRACEPTION, 1994, 49 (01) :56-72
[2]   TIME TO CONCEPTION AFTER IUD REMOVAL - IMPORTANCE OF DURATION OF USE, IUD TYPE, PELVIC INFLAMMATORY DISEASE AND AGE [J].
ANDOLSEK, L ;
TEETER, RA ;
KOZUHNOVAK, M ;
WHEELER, R ;
FORTNEY, JA ;
ROSENBERG, MJ .
INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 1986, 24 (03) :217-223
[3]  
[Anonymous], 1992, BMJ, V304, P809
[4]  
[Anonymous], 1996, IMPR ACC QUAL CAR FA
[5]  
Anwar M, 1993, Asia Oceania J Obstet Gynaecol, V19, P77
[6]  
AVONTS D, 1990, SEX TRANSM DIS, V17, P23
[7]   RECOVERY OF FERTILITY AFTER USE OF THE LEVONORGESTREL 20 MCG/D OR COPPER T-380 AG INTRAUTERINE-DEVICE [J].
BELHADJ, H ;
SIVIN, I ;
DIAZ, S ;
PAVEZ, M ;
TEJADA, AS ;
BRACHE, V ;
ALVAREZ, F ;
SHOUPE, D ;
BREAUX, H ;
MISHELL, DR ;
MCCARTHY, T ;
YO, V .
CONTRACEPTION, 1986, 34 (03) :261-267
[8]  
BLUM M, 1988, Advances in Contraceptive Delivery Systems, V4, P233, DOI 10.1007/BF01849443
[9]  
Brabin L, 1998, B WORLD HEALTH ORGAN, V76, P277
[10]   INTRAUTERINE CONTRACEPTIVE DEVICES - A REAPPRAISAL [J].
BROMHAM, DR .
BRITISH MEDICAL BULLETIN, 1993, 49 (01) :100-123