Accuracy of three-dimensional simulation in the sizing of aortic endoluminal devices

被引:16
作者
Aziz, I [1 ]
Lee, J [1 ]
Lee, JT [1 ]
Donayre, CE [1 ]
Walot, I [1 ]
Kopchok, G [1 ]
Mirahashemi, S [1 ]
Esmailzadeh, H [1 ]
White, RA [1 ]
机构
[1] Harbor UCLA Med Ctr, Div Vasc Surg, Torrance, CA 90509 USA
关键词
D O I
10.1007/s10016-001-0398-8
中图分类号
R61 [外科手术学];
学科分类号
摘要
The purpose of this study is to examine the accuracy of a 3D simulation generated by inclusion of various intensity-selected portions of spiral CT data into a proprietary software program (Preview(TM), Medical Media Systems, MMS) in preoperative and postoperative assessment of the anatomical features of abdominal aortic aneurysm (AAA). The accuracy of this software was measured against two other modalities-intravascular ultrasound (IVUS) and axial CT scan-using the IVUS as the reference. Eighty-five patients were included; 43 underwent AAA endovascular exclusion with Talent(TM) devices, and 42 with Aneurx(TM) devices. Measurement of proximal neck diameter was performed using IVUS, Preview software, and axial CT scan with manual calipers. Measurement of the AAA maximum diameter was performed using Preview software and axial CT scan; 253 measurements in the 85 patients were included. These measurements were compared by means of both linear regression and Bland-Altman agreement analysis. Our results showed that the 95% confidence interval between the Preview software and mean IVUS measurement of proximal AAA neck (3.1 and 2.5) is narrow enough for the software to be used in sizing AAA. This would be especially important for having the properly sized devices available preoperatively. The Preview software tended to be more accurate than CT scans although it was not statistically significant.
引用
收藏
页码:129 / 136
页数:8
相关论文
共 26 条
[1]  
Armon MP, 1998, J ENDOVASC SURG, V5, P222, DOI 10.1583/1074-6218(1998)005<0222:SCAVAI>2.0.CO
[2]  
2
[3]  
Beebe HG, 1997, J ENDOVASC SURG, V4, P111, DOI 10.1583/1074-6218(1997)004<0111:IMFAE>2.0.CO
[4]  
2
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   ENDOVASCULAR TREATMENT OF ABDOMINAL AORTIC OCCLUSIVE DISEASE - THE IMPACT OF STENTS AND INTRAVASCULAR ULTRASOUND IMAGING [J].
DIETHRICH, EB .
EUROPEAN JOURNAL OF VASCULAR SURGERY, 1993, 7 (03) :228-236
[7]   Comparison of magnetic resonance imaging measurements of abdominal aortic aneurysms with measurements obtained by other imaging techniques and intraoperative measurements: Possible implications for endovascular grafting [J].
Fox, AD ;
Whiteley, MS ;
Murphy, P ;
Budd, JS ;
Horrocks, M .
JOURNAL OF VASCULAR SURGERY, 1996, 24 (04) :632-638
[8]   Incidence and histologic characteristics of blebs in patients with abdominal aortic aneurysms [J].
Hunter, GC ;
Smyth, SH ;
Aguirre, ML ;
Baxter, BT ;
Bull, DA ;
King, DD ;
Wang, YP ;
Hall, KA ;
Putnam, CW .
JOURNAL OF VASCULAR SURGERY, 1996, 24 (01) :93-101
[9]   Interobserver variability in measuring the dimensions of the abdominal aorta: Comparison of ultrasound and computed tomography [J].
Jaakkola, P ;
Hippelainen, M ;
Farin, P ;
Rytkonen, H ;
Kainulainen, S ;
Partanen, K .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1996, 12 (02) :230-237
[10]   Infrarenal abdominal aortic aneurysms: Implications of CT evaluation of size and configuration for placement of endovascular aortic grafts [J].
Moritz, JD ;
Rotermund, S ;
Keating, DP ;
Oestmann, JW .
RADIOLOGY, 1996, 198 (02) :463-466