The effect of nanofiber alignment on the maturation of engineered meniscus constructs

被引:304
作者
Baker, Brendon M.
Mauck, Robert L.
机构
[1] Univ Penn, McKay Orthopaed Res Lab, Dept Orthopaed Surg, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Bioengn, Philadelphia, PA 19104 USA
关键词
tissue engineering; mechanical properties; electrospinning; anisotropy; fibrochondrocytes; mesenchymal stem cells;
D O I
10.1016/j.biomaterials.2007.01.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The fibrocartilaginous menisci are load-bearing tissues vital to the normal functioning of the knee. Removal of damaged regions of the meniscus subsequent to injury impairs knee function and predisposes patients to osteoarthritis. In this study, we employed biodegradable nanofibrous scaffolds for the tissue engineering of the meniscus. Non-aligned (NA) or fiber-aligned (AL) nanofibrous scaffolds were seeded with meniscal fibrochondrocytes (MFCs) or mesenchymal stem cells (MSCs) to test the hypothesis that fiber-alignment would augment matrix content and organization, resulting in improved mechanical properties. Additionally, we proposed that MSCs could serve as an alternative to MFCs. With time in culture, MSC- and MFC-seeded NA and AL constructs increased in cellularity and extracellular matrix (ECM) content. Counter our initial hypothesis, NA and AL constructs contained comparable amounts of ECM, although a significantly larger increase in mechanical properties was observed for AL compared to NA constructs seeded with either cell type. Cell-seeded NA constructs increased in modulus by similar to 1 MPa over 10 weeks while cell-seeded AL construct increased by > 7 MPa. Additionally, MSC-constructs yielded greater amounts of ECM and demonstrated comparable increases in mechanical properties, thereby confirming the utility of MSCs for meniscus tissue engineering. These results demonstrate that cell-seeded fiber-aligned nanofibrous scaffolds may serve as an instructive micro-pattern for directed tissue growth, reconstituting both the form and function of the native tissue. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1967 / 1977
页数:11
相关论文
共 55 条
[1]  
Adams ME, 1992, KNEE MENISCUS BASIC, P15
[2]   INVITRO MEASUREMENT OF STATIC PRESSURE DISTRIBUTION IN SYNOVIAL JOINTS .1. TIBIAL SURFACE OF THE KNEE [J].
AHMED, AM ;
BURKE, DL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03) :216-225
[3]   Modulation of anisotropy in electrospun tissue-engineering scaffolds: Analysis of fiber alignment by the fast Fourier transform [J].
Ayres, Chantal ;
Bowlin, Gary L. ;
Henderson, Scott C. ;
Taylor, Leander ;
Shultz, Jackie ;
Alexander, John ;
Telemeco, Todd A. ;
Simpson, David G. .
BIOMATERIALS, 2006, 27 (32) :5524-5534
[4]  
BAKER BM, 2006, P BIO2006 SUMM BIOEN
[5]   Chondrogenic differentiation of mesenchymal stem cells from bone marrow: Differentiation-dependent gene expression of matrix components [J].
Barry, F ;
Boynton, RE ;
Liu, BS ;
Murphy, JM .
EXPERIMENTAL CELL RESEARCH, 2001, 268 (02) :189-200
[6]   Biology of fibrocartilage cells [J].
Benjamin, M ;
Ralphs, JR .
INTERNATIONAL REVIEW OF CYTOLOGY - A SURVEY OF CELL BIOLOGY, VOL. 233, 2004, 233 :1-45
[7]   Tailoring tissue engineering scaffolds using electrostatic processing techniques: A study of poly(glycolic acid) electrospinning [J].
Boland, ED ;
Wnek, GE ;
Simpson, DG ;
Pawlowski, KJ ;
Bowlin, GL .
JOURNAL OF MACROMOLECULAR SCIENCE-PURE AND APPLIED CHEMISTRY, 2001, 38 (12) :1231-1243
[8]   Tissue engineering of the meniscus [J].
Buma, P ;
Ramrattan, NN ;
van Tienen, TG ;
Veth, RPH .
BIOMATERIALS, 2004, 25 (09) :1523-1532
[9]  
CLARK CR, 1983, J BONE JOINT SURG AM, V65, P538, DOI 10.2106/00004623-198365040-00018
[10]   Long-term outcome for large meniscal defects treated with small intestinal submucosa in a dog model [J].
Cook, JL ;
Fox, DB ;
Malaviya, P ;
Tomlinson, JL ;
Kuroki, K ;
Cook, CR ;
Kladakis, S .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (01) :32-42