Physical characterization of controlled release of paclitaxel from the TAXUSTM Express2TM drug-eluting stent

被引:159
作者
Ranade, SV
Miller, KM
Richard, RE
Chan, AK
Allen, MJ
Helmus, MN
机构
[1] Boston Sci Corp, Corp Res & Adv Technol Dev, Natick, MA 01760 USA
[2] Biometrol Inc, Alameda, CA 94501 USA
关键词
drug-eluting stent; paclitaxel; atomic force microscopy (AFM); drug delivery; block copolymers;
D O I
10.1002/jbm.a.30188
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The polymer carrier technology in the TAXUST(TM) drug-eluting stent consists of a thermoplastic elastomer poly (styrene-b-isobutylene-b-styrene) (SIBS) with microphase-separated morphology resulting in optimal properties for a drug-delivery stent coating. Comprehensive physical characterization of the stent coatings and cast film formulations showed that paclitaxel (PTx) exists primarily as discrete nanoparticles embedded in the SIBS matrix. Thermal and chemical analysis did not show any evidence of solubility of PTx in SIBS or of any molecular miscibility between PTx and SIBS. Atomic force microscope data images revealed for the first time three-dimensional stent coating surfaces at high spatial resolutions in air and in situ under phosphate-buffered saline as drug was released. PTx release involves the initial dissolution of drug particles from the PTx/SIBS coating surface. Morphological examination of the stent coatings in vitro supported an early burst release in most formulations because of surface PTx followed by a sustained slower release of PTx from the bulk coating. The in vitro PTx release kinetics were dependent on the formulation and correlated to the drug-to-polymer ratio. Atomic force microscopy analysis confirmed this correlation and further supported the concept of a matrix-based drug-release coating. (C) 2004 Wiley Periodicals, Inc.
引用
收藏
页码:625 / 634
页数:10
相关论文
共 34 条
[1]   Antithrombotic potential of polymer-coated stents eluting platelet glycoprotein IIb/IIIa receptor antibody [J].
Aggarwal, RK ;
Ireland, DC ;
Azrin, MA ;
Ezekowitz, MD ;
deBono, DP ;
Gershlick, AH .
CIRCULATION, 1996, 94 (12) :3311-3317
[2]  
ANDREWS RJ, 1999, POLYM HDB, P198
[3]   Investigation of the rheological and mechanical properties of a polystyrene-polyisobutylene-polystyrene triblock copolymer and its blends with polystyrene [J].
Antony, P ;
Puskas, JE ;
Kontopoulou, M .
POLYMER ENGINEERING AND SCIENCE, 2003, 43 (01) :243-253
[4]   Coated scents for the prevention of restenosis: Part II [J].
Babapulle, MN ;
Eisenberg, MJ .
CIRCULATION, 2002, 106 (22) :2859-2866
[5]  
Belotti D, 1996, CLIN CANCER RES, V2, P1843
[6]  
BERG E, 1995, Patent No. 5464650
[7]   Drug-eluting stents: new era and new concerns [J].
Bhatia, V ;
Bhatia, R ;
Dhindsa, M .
POSTGRADUATE MEDICAL JOURNAL, 2004, 80 (939) :13-18
[8]  
Blagosklonny MV, 2004, CELL CYCLE, V3, P1050
[9]  
CHEN J, UNPUB CHRACTERIZATIO
[10]  
Chieffo A, 2004, HERZ, V29, P147, DOI 10.1007/s00059-004-2555-7