Characterizing Human Cancer Metabolomics with ex vivo 1H HRMAS MRS

被引:21
作者
DeFeo, Elita M. [1 ]
Cheng, Leo L. [1 ,2 ]
机构
[1] Harvard Univ, Sch Med, Dept Pathol, Massachusetts Gen Hosp, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Dept Radiol, Massachusetts Gen Hosp, Boston, MA 02115 USA
关键词
Magnetic resonance spectroscopy; Magic angle spinning; Metabolomics; diagnosis; Lung; Breast; Prostate; Brain; Colorectal; Cervical; Cancer; Clinical application; MAGNETIC-RESONANCE-SPECTROSCOPY; MAS NMR-SPECTROSCOPY; HR-MAS; PROSTATE-CANCER; CLINICAL-APPLICATIONS; PROTON NMR; RESOLUTION; TISSUE; METABOLITES; QUANTIFICATION;
D O I
10.1177/153303461000900407
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Publications of proton high resolution magic angle spinning (H-1 HRMAS) magnetic resonance spectroscopy (MRS) and its role in identification of metabolic markers for human cancer reported between 2005 and 2009 are reviewed according the anatomic sites of cancer: lung, breast, prostate, brain, colorectal, and cervical. Limited and insufficient screening options for the general public have indicated a need for more advanced tests that can identify and locate cancer at an early stage. H-1 HRMAS MRS is a valuable tool that can elucidate relevant biological metabolite information that is being used to distinguish cancer from benign tissue, and even classify types of tumors. Researchers are working to translate this ex vivo spectroscopy information into an in vivo system that could be implemented in cancer clinics. For instance, in the case of lung cancer, the goal is to identify the at risk population through a simple blood test, which would be the first level of screening. From these tests, patients identified as at risk will be able to undergo further non-invasive radiological testing for diagnostic purposes. Not only will this ex vivo technology become a valuable diagnostic tool, it will also provide a way to monitor treatments on an individual basis so they can be adjusted accordingly for the best possible outcome.
引用
收藏
页码:381 / 391
页数:11
相关论文
共 47 条
[1]   Mortality Results from a Randomized Prostate-Cancer Screening Trial [J].
Andriole, Gerald L. ;
Grubb, Robert L., III ;
Buys, Saundra S. ;
Chia, David ;
Church, Timothy R. ;
Fouad, Mona N. ;
Gelmann, Edward P. ;
Kvale, Paul A. ;
Reding, Douglas J. ;
Weissfeld, Joel L. ;
Yokochi, Lance A. ;
Crawford, E. David ;
O'Brien, Barbara ;
Clapp, Jonathan D. ;
Rathmell, Joshua M. ;
Riley, Thomas L. ;
Hayes, Richard B. ;
Kramer, Barnett S. ;
Izmirlian, Grant ;
Miller, Anthony B. ;
Pinsky, Paul F. ;
Prorok, Philip C. ;
Gohagan, John K. ;
Berg, Christine D. .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 360 (13) :1310-1319
[2]   Molecular classification of brain tumor biopsies using solid-state magic angle spinning proton magnetic resonance spectroscopy and robust classifiers [J].
Andronesi, Ovidiu C. ;
Blekas, Konstantinos D. ;
Mintzopoulos, Dionyssios ;
Astrakas, Loukas ;
Black, Peter M. ;
Tzika, A. Aria .
INTERNATIONAL JOURNAL OF ONCOLOGY, 2008, 33 (05) :1017-1025
[3]   Reduction of spinning sidebands in proton NMR of human prostate tissue with slow high-resolution magic angle spinning [J].
Burns, MA ;
Taylor, JL ;
Wu, CL ;
Zepeda, AG ;
Bielecki, A ;
Cory, D ;
Cheng, LL .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (01) :34-42
[4]   Determination of metabolite concentrations in human brain tumour biopsy samples using HR-MAS and ERETIC measurements [J].
Carmen Martinez-Bisbal, M. ;
Monleon, Daniel ;
Assemat, Olivier ;
Piotto, Martial ;
Piquer, Jose ;
Luis Llacer, Jose ;
Celda, Bernardo .
NMR IN BIOMEDICINE, 2009, 22 (02) :199-206
[5]   Metabolic Profiling of Human Colorectal Cancer Using High-Resolution Magic Angle Spinning Nuclear Magnetic Resonance (HR-MAS NMR) Spectroscopy and Gas Chromatography Mass Spectrometry (GC/MS) [J].
Chan, Eric Chun Yong ;
Koh, Poh Koon ;
Mal, Mainak ;
Cheah, Peh Yean ;
Eu, Kong Weng ;
Backshall, Alexandra ;
Cavill, Rachel ;
Nicholson, Jeremy K. ;
Keun, Hector C. .
JOURNAL OF PROTEOME RESEARCH, 2009, 8 (01) :352-361
[6]  
Cheng LL, 2000, NEURO-ONCOLOGY, V2, P87, DOI 10.1093/neuonc/2.2.87
[7]   Enhanced resolution of proton NMR spectra of malignant lymph nodes using magic-angle spinning [J].
Cheng, LL ;
Lean, CL ;
Bogdanova, A ;
Wright, SC ;
Ackerman, JL ;
Brady, TJ ;
Garrido, L .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (05) :653-658
[8]   Metabolic characterization of human prostate cancer with tissue magnetic resonance spectroscopy [J].
Cheng, LL ;
Burns, MA ;
Taylor, JL ;
He, WL ;
Halpern, EF ;
McDougal, WS ;
Wu, CL .
CANCER RESEARCH, 2005, 65 (08) :3030-3034
[9]   Quantitative neuropathology by high resolution magic angle spinning proton magnetic resonance spectroscopy [J].
Cheng, LL ;
Ma, MJ ;
Becerra, L ;
Ptak, T ;
Tracey, I ;
Lackner, A ;
Gonzalez, RG .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (12) :6408-6413
[10]   Non-invasive detection of glycine as a biomarker of malignancy in childhood brain tumours using in-vivo 1H MRS at 1.5 Tesla confirmed by ex-vivo, high-resolution magic-angle spinning NMR [J].
Davies, N. P. ;
Wilson, M. ;
Natarajan, K. ;
Sun, Y. ;
MacPherson, L. ;
Brundler, M-A. ;
Arvanitis, T. N. ;
Grundy, R. G. ;
Peet, A. C. .
NMR IN BIOMEDICINE, 2010, 23 (01) :80-87