Development and validation of a sensitive liquid chromatographic-tandem mass spectrometric method for the determination of cromolyn sodium in human plasma

被引:15
作者
Lin, ZPJ
Abbas, R
Rusch, LM
Shum, L
机构
[1] Avantix Labs Inc, New Castle, DE 19720 USA
[2] Emisphere Technol Inc, Tarrytown, NY 10591 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2003年 / 788卷 / 01期
关键词
cromolyn sodium;
D O I
10.1016/S1570-0232(02)01041-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cromolyn sodium is a safe compound with potent anti-allergic properties when used locally or topically. Clinical data from systemic exposure is not available because of the poor GI absorption when given orally. In order to evaluate a new approach to enhance the absorption and bioavailability of cromolyn sodium, a sensitive assay was needed to support an oral-dose study in humans. This paper describes a liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method for the analysis of cromolyn sodium in human plasma. The method consists of a two-step extraction with subsequent analysis using a high-performance liquid chromatography electrospray tandem mass spectrometer system. The compounds were eluted isocratically on a C-18 column followed by a backflush. The total run time is 6 min. The standard curve of cromolyn sodium was over the range of 0.313 to 750 ng/mL with a lower limit of quantitation (LLOQ) of 0.313 ng/mL when 0.5 mL of plasma was used for analysis. The percent coefficient of variation (CV) for accuracy and precision (inter-assay and intra-assay) was less than 15% over the validated concentration range and the coefficients of determination, r(2), were >0.991577. The method is simple, sensitive, and selective, and has been successfully utilized for oral cromolyn sodium clinical studies. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 13 条
[1]  
[Anonymous], GUID IND BIOAN METH
[2]  
Dolan JW, 2001, LC GC N AM, V19, P32
[3]  
HOGBEN CAM, 1959, J PHARMACOL EXP THER, V125, P275
[4]   Development and validation of a stability-indicating HPLC method for the determination of cromolyn sodium and its related substances in cromolyn sodium drug substance and cromolyn sodium inhalation solution, 1.0% [J].
Mansfield, R ;
Huang, J ;
Thatcher, S ;
Miller, RB ;
Davis, CW .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1999, 22 (14) :2187-2209
[5]   Determination of disodium cromoglycate in human urine by high-performance liquid chromatography with post-column photoirradiation-fluorescence detection [J].
Mawatari, K ;
Mashiko, S ;
Sate, Y ;
Usui, Y ;
Iinuma, F ;
Watanabe, M .
ANALYST, 1997, 122 (07) :715-717
[6]   Determination of sodium cromoglycate in human plasma by liquid chromatography-mass spectrometry in the turbo ion spray mode [J].
Ozoux, ML ;
Girault, J ;
Malgouyat, JM ;
Pasquier, O .
JOURNAL OF CHROMATOGRAPHY B, 2001, 765 (02) :179-185
[7]   High performance liquid chromatographic determination of sodium cromoglycate [J].
Segall, A ;
Vitale, F ;
Ricci, R ;
Giancaspro, G ;
Pizzorno, MT .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1997, 23 (08) :839-842
[8]  
SILVERMAN M, 1979, J ALLERGY CLIN IMMUN, V3, P378
[9]   DOUBLE-BLIND CROSSOVER TRIAL COMPARING BECLOMETHASONE DIPROPIONATE AND SODIUM CROMOGLYCATE IN PERENNIAL ALLERGIC RHINITIS [J].
TANDON, MK ;
STRAHAN, EG .
CLINICAL ALLERGY, 1980, 10 (04) :459-462
[10]  
TAYLOR G, 1971, Clinical Allergy, V1, P189, DOI 10.1111/j.1365-2222.1971.tb03018.x