Quality control of surgical and interventional procedures: a review of the CUSUM

被引:103
作者
Biau, David J.
Resche-Rigon, Mathieu
Godiris-Petit, Gae
Nizard, Remy S.
Porcher, Raphael
机构
[1] Univ Paris 07, INSERM, U717, Hop St Louis,Dept Biostat & Informat Med,APHP, Paris, France
[2] Univ Paris 07, Hop St Louis, AP HP, Serv Chirurg Gen Digest & Endocrinienne, Paris, France
[3] Univ Paris 07, Hop Lariboisiere, APHP, Serv Chirurg Orthoped & Traumatol, Paris, France
来源
QUALITY & SAFETY IN HEALTH CARE | 2007年 / 16卷 / 03期
关键词
D O I
10.1136/qshc.2006.020776
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: The report of the CUSUM across surgical and interventional procedures has spawned a fair confusion in the literature. Aim: To assess the use of the CUSUM and to clarify its utilisation in the perspective of future studies. Nature of the study: Retrospective review. Methods: A systematic literature search of Medline was carried out. From each article, data regarding the design of the study, the specialty, the performance criterion, the unit under control, the methodology and the model of the CUSUM used, the use of a graph, the use of a test and the type of test applied were retrieved. Results: 31 studies were found relevant. The design was mainly retrospective for the analysis of the learning curve. The main performance criteria under control were morbidity, mortality and success of the procedure. A graph was plotted in all studies as a CUSUM plot or as cumulative sums of non-negative values. A test was used in 17 studies. Mislabelling of the plot and the test, and misuse of control limits were the most commonly reported mistakes. Conclusion: The CUSUM tool is not yet properly reported in the surgical literature. Therefore, reporting of the CUSUM should be clarified and standardised before its use widens.
引用
收藏
页码:203 / 207
页数:5
相关论文
共 48 条
[1]   THE HIDDEN EFFECT OF TIME [J].
ALTMAN, DG ;
ROYSTON, JP .
STATISTICS IN MEDICINE, 1988, 7 (06) :629-637
[2]  
[Anonymous], 1931, EC CONTROL QUALITY M
[3]   A ventilation-exchange bougie for fibreoptic intubations with the laryngeal mask airway [J].
Atherton, DPL ;
OSullivan, E ;
Lowe, D ;
Charters, P .
ANAESTHESIA, 1996, 51 (12) :1123-1126
[4]   Cusum analysis of trends in operative selection and conversion rates for laparoscopic cholecystectomy [J].
Bartlett, A ;
Parry, B .
ANZ JOURNAL OF SURGERY, 2001, 71 (08) :453-456
[5]   The use of the Cusum Technique in the assessment of trainee competence in new procedures [J].
Bolsin, S ;
Colson, M .
INTERNATIONAL JOURNAL FOR QUALITY IN HEALTH CARE, 2000, 12 (05) :433-438
[6]   The construction of learning curves for basic skills in anesthetic procedures: An application for the cumulative sum method [J].
de Oliveira, GR .
ANESTHESIA AND ANALGESIA, 2002, 95 (02) :411-416
[7]  
DELEVAL MR, 1994, J THORAC CARDIOV SUR, V107, P914
[8]  
DESAINTONGE DMC, 1974, LANCET, V1, P120
[9]   Cumulative sum failure analysis of the learning curve with endovascular abdominal aortic aneurysm repair [J].
Forbes, TL ;
DeRose, G ;
Kribs, SW ;
Harris, KA .
JOURNAL OF VASCULAR SURGERY, 2004, 39 (01) :102-108
[10]   A CUSUM analysis of ruptured abdominal aortic aneurysm repair [J].
Forbes, TL ;
De Rose, G ;
Harris, KA .
ANNALS OF VASCULAR SURGERY, 2002, 16 (05) :527-533