Periodically changing ventilator circuits is not necessary to prevent ventilator-associated pneumonia when a heat and moisture exchanger is used

被引:43
作者
Lorente, L
Lecuona, M
Galván, PR
Ramos, MJ
Mora, ML
Sierra, A
机构
[1] Hosp Univ Canarias, Dept Crit Care, San Cristobal la Laguna 38320, Santa Cruz Tene, Spain
[2] Hosp Univ Canarias, Dept Microbiol, San Cristobal la Laguna 38320, Santa Cruz Tene, Spain
关键词
D O I
10.1086/502347
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
OBJECTIVE: To analyze the efficacy of periodically changing ventilator circuits for decreasing the rate of ventilator-associated pneumonia when a heat and moisture exchanger (HME) is used for humidification. The Centers for Disease Control and Prevention recommended not changing the circuits periodically. DESIGN: Randomized, controlled trial conducted between April 2001 and August 2002. SETTING: A 24-bed, medical-surgical intensive care unit in a 650-bed, tertiary-care hospital. PATIENTS: All patients requiring mechanical ventilation during more than 72 hours from April 2001 to August 2002. INTERVENTIONS: Patients were randomized into two groups: (1) ventilation with change of ventilator circuits every 48 hours and (2) ventilation with no change of circuits. Throat swabs were taken on admission and twice weekly until discharge to classify pneumonia as endogenous or exogenous. RESULTS: Three hundred four patients (143 from group 1 and 161 from group 2) with similar characteristics (age, gender, Acute Physiology and Chronic Health Evaluation 11 score, diagnostic group, and mortality) were analyzed. There was no significant difference in the rate of pneumonia between the groups (23.1% vs 23.0% and 15.5 vs 14.8 per 1,000 ventilator-days). There was no significant difference in the incidence of exogenous pneumonia per 1,000 days of mechanical ventilation (1.71 vs 1.25). There was no difference in the distribution of microorganisms causing pneumonia. CONCLUSIONS: Circuit change using an HME for humidification does not decrease pneumonia and represents an unnecessary cost.
引用
收藏
页码:1077 / 1082
页数:6
相关论文
共 35 条
[1]  
ALFREDSON T, 1994, RESP CARE, V39, P161
[2]  
BECK A, 1968, LANCET, V1, P533
[3]   Mortality rate attributable to ventilator-associated nosocomial pneumonia in an adult intensive care unit: A prospective case-control study [J].
Bercault, N ;
Boulain, T .
CRITICAL CARE MEDICINE, 2001, 29 (12) :2303-2309
[4]   Ventilator-associated pneumonia [J].
Chastre, J ;
Fagon, JY .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 165 (07) :867-903
[5]   EFFECT OF INTENSIVE-CARE UNIT NOSOCOMIAL PNEUMONIA ON DURATION OF STAY AND MORTALITY [J].
CRAIG, CP ;
CONNELLY, S .
AMERICAN JOURNAL OF INFECTION CONTROL, 1984, 12 (04) :233-238
[6]   CONTAMINATION OF MECHANICAL VENTILATORS WITH TUBING CHANGES EVERY 24 OR 48 HOURS [J].
CRAVEN, DE ;
CONNOLLY, MG ;
LICHTENBERG, DA ;
PRIMEAU, PJ ;
MCCABE, WR .
NEW ENGLAND JOURNAL OF MEDICINE, 1982, 306 (25) :1505-1509
[7]  
CRAVEN DE, 1984, AM REV RESPIR DIS, V129, P625
[8]  
CRAVEN DE, 1986, AM REV RESPIR DIS, V133, P792
[9]   PROSPECTIVE-STUDY OF NOSOCOMIAL PNEUMONIA AND OF PATIENT AND CIRCUIT COLONIZATION DURING MECHANICAL VENTILATION WITH CIRCUIT CHANGES EVERY 48 HOURS VERSUS NO CHANGE [J].
DREYFUSS, D ;
DJEDAINI, K ;
WEBER, P ;
BRUN, P ;
LANORE, JJ ;
RAHMANI, J ;
BOUSSOUGANT, Y ;
COSTE, F .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 143 (04) :738-743
[10]   NOSOCOMIAL PNEUMONIA IN VENTILATED PATIENTS - A COHORT STUDY EVALUATING ATTRIBUTABLE MORTALITY AND HOSPITAL STAY [J].
FAGON, JY ;
CHASTRE, J ;
HANCE, AJ ;
MONTRAVERS, P ;
NOVARA, A ;
GIBERT, C .
AMERICAN JOURNAL OF MEDICINE, 1993, 94 (03) :281-288