Simultaneous determination of losartan and active metabolite EXP3174 in rat plasma by HPLC with column switching

被引:26
作者
Lee, H
Shim, HO
Lee, HS
机构
[1] KOREA RES INST CHEM TECHNOL,SCREENING & TOXICOL CTR,TAEJON 305606,SOUTH KOREA
[2] WONKWANG UNIV,COLL PHARM,IKSAN 570749,SOUTH KOREA
关键词
column liquid chromatography; column-switching; losartan and EXP3174 in plasma;
D O I
10.1007/BF02271053
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new liquid chromatographic method with column-switching has been developed for the simultaneous determination of losartan and its active metabolite, EXP3174 in rat plasma. The plasma sample was injected onto a precolumn of LiChroprep RP-8 after dilution with 5% acetonitrile in 50 mM phosphoric acid. Polar plasma components were eluted using this diluent. After valve switching, the concentrated drugs were eluted in the back-flush mode and separated by an Inertsil ODS-2 column with acetonitrile-acetate buffer. The method showed excellent precision, accuracy and speed with detection limit 20 ng mL(-1). Total analysis time per sample was less than 40 min and the coefficients of variation for intra and inter-assay were 4.8%. This method has been successfully applied after oral administration of losartan to rat plasma samples.
引用
收藏
页码:39 / 42
页数:4
相关论文
共 19 条
[1]   EFFECTS OF THE NONPEPTIDE ANGIOTENSIN-II RECEPTOR ANTAGONIST DUP 753 ON BLOOD-PRESSURE AND RENAL FUNCTIONS IN SPONTANEOUSLY HYPERTENSIVE PH DOGS [J].
BOVEE, KC ;
WONG, PC ;
TIMMERMANS, PBMWM ;
THOOLEN, MJMC .
AMERICAN JOURNAL OF HYPERTENSION, 1991, 4 (04) :S327-S333
[2]  
DEGRAAF GL, 1993, J PHARMACOL EXP THER, V264, P6
[3]   SIMULTANEOUS DETERMINATION OF A NOVEL ANGIOTENSIN-II RECEPTOR BLOCKING-AGENT, LOSARTAN, AND ITS METABOLITE IN HUMAN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FURTEK, CI ;
LO, MW .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 573 (02) :295-301
[4]  
JANG WC, 1994, J LIQ CHROMATOGR, V17, P1735
[5]   SIMULTANEOUS DETERMINATION OF IBUPROXAM AND IBUPROFEN IN HUMAN PLASMA BY HPLC WITH COLUMN-SWITCHING [J].
JUNG, ES ;
LEE, HS ;
RHO, JK ;
KWON, KI .
CHROMATOGRAPHIA, 1993, 37 (11-12) :618-622
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF DICLOFENAC SODIUM IN PLASMA USING COLUMN-SWITCHING TECHNIQUE FOR SAMPLE CLEANUP [J].
LEE, HS ;
KIM, EJ ;
ZEE, OP ;
LEE, YJ .
ARCHIV DER PHARMAZIE, 1989, 322 (11) :801-806
[7]   COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF CIPROFLOXACIN IN SERUM USING AMBERLITE XAD-7 [J].
LEE, HS ;
ZEE, OP ;
WOO, BH ;
LEE, YJ .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-ENVIRONMENTAL SCIENCE AND ENGINEERING & TOXIC AND HAZARDOUS SUBSTANCE CONTROL, 1991, 26 (07) :1253-1265
[8]   SIMULTANEOUS DETERMINATION OF CEFAMANDOLE AND CEFAMANDOLE NAFATE IN HUMAN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN SWITCHING [J].
LEE, HS ;
ZEE, OP ;
KWON, KI .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 528 (02) :425-433
[9]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF RIFAPENTINE IN SERUM USING COLUMN SWITCHING [J].
LEE, HS ;
SHIN, HC ;
HAN, SS ;
ROH, JK .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 574 (01) :175-178
[10]   SIMULTANEOUS DETERMINATION OF AMPICILLIN AND METAMPICILLIN IN BIOLOGICAL-FLUIDS USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING [J].
LEE, HY ;
LEE, JS ;
LEE, HS .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 664 (02) :335-340