Comparison of periodontal and peri-implant probing by depth-force pattern analysis

被引:71
作者
Mombelli, A [1 ]
Muhle, T [1 ]
Bragger, U [1 ]
Lang, NP [1 ]
Burgin, WB [1 ]
机构
[1] Univ Bern, Sch Dent Med, CH-3010 Bern, Switzerland
关键词
peri-implant probing; probing force; tissue resistance;
D O I
10.1034/j.1600-0501.1997.080602.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to compare the tissue resistance to probing and the accuracy of depth determination at different force levels around implants and teeth. In 11 subjects 1 implant and 1 tooth at a comparable location and with comparable probing depth were investigated. The sites were located on either the mesial or distal aspect of the tooth and the implant. A probing device was used which allowed simultaneous monitoring of probing force and probe penetration and which standardized the insertion pathway for repeated measurements. The probing instrument was fitted with an attachment for an aiming device to take a radiograph with the probe tip in the sulcus, using a standardized projection geometry. Probing depth values were determined at 0.25, 0.50, 0.75, 1.00 and 1.25 N probing force. The standard error of the individual measurement (S-i), evaluated by comparison of repeated measurements in the same session, was 0.2 mm on implants and 0.1 mm on teeth. For implants there was a trend for slightly better reproducibility at higher force levels. Curve analysis of depth force patterns showed that a change in probing force had more impact on the depth reading in the peri-implant than in the periodontal situation. The mean distance between the probe tip and the periimplant bone crest amounted to 0.75+/-0.60 mm at 0.25 N probing force. It is concluded that peri-implant probing depth measurements are more sensitive to force variation than periodontal pocket probing.
引用
收藏
页码:448 / 454
页数:7
相关论文
共 32 条
[1]   EFFECT OF TRAINING AND PROBING FORCE ON THE REPRODUCIBILITY OF POCKET DEPTH MEASUREMENTS [J].
ABBAS, F ;
HART, AAM ;
OOSTING, J ;
VANDERVELDEN, U .
JOURNAL OF PERIODONTAL RESEARCH, 1982, 17 (02) :226-234
[2]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[3]   MEASURING AND INTERPRETING INCREASES IN PROBING DEPTH AND ATTACHMENT LOSS [J].
AEPPLI, DM ;
BOEN, JR ;
BANDT, CL .
JOURNAL OF PERIODONTOLOGY, 1985, 56 (05) :262-264
[4]  
ALBREKTSSON T, 1994, PROCEEDINGS OF THE 1ST EUROPEAN WORKSHOP ON PERIODONTOLOGY, P365
[5]  
Alcoforado G A, 1991, J Parodontol, V10, P11
[6]   REPRODUCIBILITY OF PROBING ATTACHMENT LEVEL MEASUREMENTS [J].
BADERSTEN, A ;
NILVEUS, R ;
EGELBERG, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1984, 11 (07) :475-485
[7]  
BECKER W, 1990, International Journal of Oral and Maxillofacial Implants, V5, P31
[8]   PREVALENCE OF CHRONIC PERIODONTAL-DISEASE USING PROBING DEPTH AS A DIAGNOSTIC-TEST [J].
BERGSTROM, J ;
ELIASSON, S .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1989, 16 (09) :588-592
[9]  
Borghetti A, 1984, J Parodontol, V3, P19
[10]   Tissue integration of non-submerged implants 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants [J].
Buser, D. ;
Weber, H-P ;
Lang, N. P. .
CLINICAL ORAL IMPLANTS RESEARCH, 1990, 1 (01) :33-40