Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention

被引:489
作者
Pibarot, P [1 ]
Dumesnil, JG [1 ]
机构
[1] Univ Laval, Laval Hosp, Quebec Heart Inst, St Foy, PQ G1V 4G5, Canada
基金
英国医学研究理事会;
关键词
D O I
10.1016/S0735-1097(00)00859-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Prosthesis-patient mismatch is present when the effective orifice area of the inserted prosthetic valve is less than that of a normal human valve. This is a frequent problem in patients undergoing aortic valve replacement, and its main hemodynamic consequence is the generation of high transvalvular gradients through normally functioning prosthetic valves. The purposes of this report are to present an update on the concept of aortic prosthesis-patient mismatch and to review the present knowledge with regard to its impact on hemodynamic status, functional capacity, morbidity and mortality. Also, we propose a simple approach for the prevention and clinical management of this phenomenon because it can be largely avoided if certain simple factors are taken into consideration before the operation. (T Am Coil Cardiol 2000;36:1131-41) (C) 2000 by the American College of Cardiology.
引用
收藏
页码:1131 / 1141
页数:11
相关论文
共 123 条
[1]   PROGNOSTIC FACTORS IN AORTIC-VALVE REPLACEMENT ASSOCIATED WITH NARROW AORTIC ROOTS - AN ANALYSIS USING THE PROPORTIONAL HAZARD MODEL [J].
ABDELNOOR, M ;
HALL, KV ;
NITTERHAUGE, S ;
LINDBERG, H ;
OVRUM, E .
SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1986, 20 (03) :227-232
[2]  
BARNER HB, 1994, J CARDIAC SURG SS, V9, pS154
[3]   ADAPTATION OF THE LEFT-VENTRICULAR FUNCTION PARAMETERS TO DYNAMIC EXERCISE IN AORTIC-STENOSIS [J].
BASSAND, JP ;
BA, SA ;
DUCELLIER, D ;
LUSSON, JR ;
PEYCELON, P ;
FAIVRE, R ;
CARDOT, JC ;
CASSAGNES, J ;
JALLUT, J ;
MAURAT, JP .
EUROPEAN HEART JOURNAL, 1988, 9 :87-92
[4]   EFFECT OF PROSTHETIC AORTIC-VALVE DESIGN ON THE DOPPLER-CATHETER GRADIENT CORRELATION - AN INVITRO STUDY OF NORMAL ST-JUDE, MEDTRONIC-HALL, STARR-EDWARDS AND HANCOCK VALVES [J].
BAUMGARTNER, H ;
KHAN, S ;
DEROBERTIS, M ;
CZER, L ;
MAURER, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) :324-332
[5]   DISCREPANCIES BETWEEN DOPPLER AND CATHETER GRADIENTS IN AORTIC PROSTHETIC VALVES INVITRO - A MANIFESTATION OF LOCALIZED GRADIENTS AND PRESSURE RECOVERY [J].
BAUMGARTNER, H ;
KHAN, S ;
DEROBERTIS, M ;
CZER, L ;
MAURER, G .
CIRCULATION, 1990, 82 (04) :1467-1475
[6]   Overestimation of catheter gradients by Doppler ultrasound in patients with aortic stenosis: A predictable manifestation of pressure recovery [J].
Baumgartner, H ;
Stefenelli, T ;
Niederberger, J ;
Schima, H ;
Maurer, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (06) :1655-1661
[7]   DEATH AND OTHER TIME-RELATED EVENTS AFTER VALVE-REPLACEMENT [J].
BLACKSTONE, EH ;
KIRKLIN, JW .
CIRCULATION, 1985, 72 (04) :753-767
[8]   CLINICAL AND HEMODYNAMIC PERFORMANCE OF THE 19-MM CARPENTIER-EDWARDS PORCINE BIOPROSTHESIS [J].
BOJAR, RM ;
RASTEGAR, H ;
PAYNE, DD ;
MACK, CA ;
SCHWARTZ, SL .
ANNALS OF THORACIC SURGERY, 1993, 56 (05) :1141-1147
[9]  
Bonchek LI, 1998, ANN THORAC SURG, V66, P984
[10]  
BONCHEK LI, 1987, J THORAC CARDIOV SUR, V94, P632