An on-chip detector based on backscatter interferometry has been developed to perform subnanoliter-volume refractive index measurements. The detection system consists of a simple, folded optical train based on the interaction of a laser beam and an etched channel, consisting of two radii joined by a flat portion, thus defining a curved surface in the shape of a hemisphere in a silica (glass) plate. The backscattered light from the channel takes on the form of a high-contrast interference pattern that contains information related to the bulk properties of the fluid contained within the probe volume. Positional changes of the interference pattern (fringes) allow for the determination of Delta n at the 10(-6) level, corresponding to 743 mu M or 139 x 10(-15) mol or 12.8 x 10(-12) g Of sucrose, in a probe volume of only 188 x 10(-12) L. A theoretical model of the on-chip backscatter interferometric detector has also been developed, evaluated, and found to be in agreement with experimental data. It is shown that the model can be used to predict general system performance for changes in the optical train such as the chip's wall thickness and channel diameter.
引用
收藏
页码:2690 / 2695
页数:6
相关论文
共 39 条
[1]   Sub-microliter electrochemiluminescence detector - A model for small volume analysis systems [J].
Arora, A ;
de Mello, AJ ;
Manz, A .
ANALYTICAL COMMUNICATIONS, 1997, 34 (12) :393-395
[2]   DETECTING SINGLE MOLECULES IN LIQUIDS [J].
BARNES, MD ;
WHITTEN, WB ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :A418-A423
[3]   Surface plasmon resonance multisensing [J].
Berger, CEH ;
Beumer, TAM ;
Kooyman, RPH ;
Greve, J .
ANALYTICAL CHEMISTRY, 1998, 70 (04) :703-706
[4]  
BORN XX, 1975, PRINCIPLES OPTICS
[5]   SUBNANOLITER LASER-BASED REFRACTIVE-INDEX DETECTOR FOR 0.25-MM ID MICROBORE LIQUID-CHROMATOGRAPHY - REVERSED-PHASE SEPARATION OF NANOGRAM AMOUNTS OF SUGARS [J].
BORNHOP, DJ ;
NOLAN, TG ;
DOVICHI, NJ .
JOURNAL OF CHROMATOGRAPHY, 1987, 384 :181-187
[6]   MICROVOLUME INDEX OF REFRACTION DETERMINATIONS BY INTERFEROMETRIC BACKSCATTER [J].
BORNHOP, DJ .
APPLIED OPTICS, 1995, 34 (18) :3234-3239
[7]  
Bornhop DJ, 1994, US Patent, Patent No. [5,325,170, 5325170]
[8]   Holographic refractive index detector for application in microchip-based separation systems [J].
Burggraf, N ;
Krattiger, B ;
de Mello, AJ ;
de Rooij, NF ;
Manz, A .
ANALYST, 1998, 123 (07) :1443-1447
[9]  
CHEN G, 1997, CRIT REV NEUROBIOL, V11, P1519
[10]   Silicon microtechnology and microstructures in separation science [J].
Fintschenko, Y ;
van den Berg, A .
JOURNAL OF CHROMATOGRAPHY A, 1998, 819 (1-2) :3-12