Steroid-eluting epicardial pacing electrodes: Six year experience of pacing thresholds in a growing pediatric population

被引:34
作者
Cutler, NG
Karpawich, PP
Cavitt, D
Hakimi, M
Walters, HL
机构
[1] Wayne State Univ, Childrens Hosp Michigan, Cardiol Sect, Detroit, MI 48201 USA
[2] Wayne State Univ, Childrens Hosp Michigan, Cardiovasc Surg Sect, Detroit, MI USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1997年 / 20卷 / 12期
关键词
steroid; electrode; pacemaker; pediatric;
D O I
10.1111/j.1540-8159.1997.tb05464.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
indications for pacemaker implantation in the pediatric population often include sinus or atrioventricular node dysfunction following surgery for congenital heart defects. However, patient size, cardiac defects, and vascular and valvular concerns may limit transvenous lead utilization. Since the epicardial surface of these patients often exhibits variable degrees of fibrosis from scar tissue formation or pericardial adhesions, chronic low output (2.5/1.6 V, 0.3 ms) epicardial pacing from implant is not currently recommended in children due to frequent threshold changes and electrode exit block. As a result, pacing in children is often viewed as a less efficient system than in adults. The addition of steroid combined with newer low threshold electrode designs however stabilizes the electrode-tissue interface and eliminates postimplant changes seen with standard smooth surface electrodes potentially permitting efficient chronic pacemaker application to all patient ages. The stability of chronic low output epicardial pacing with steroid-eluting electrodes was prospectively studied in 22 patients (ages 2 days-18.5 years, median 3.5 years) for up to 6 years. Chronic pulse width thresholds were compared according to implant site and association of prior cardiac surgery. A total of 26 pacing leads were implanted. The acute implant mean pulse width threshold (2.5 V) for all the electrodes studied was 0.10 ms +/- 0.05 ms. Stable low thresholds were maintained for up to 6 years without significant variation from implant. Mean ventricular pulse width thresholds (0.12 ms +/- 0.05 ms) were significantly higher (P < 0.001) than atrial thresholds (0.06 ms +/- 0.03 ms) at implant and throughout the study period. The thresholds in the patients following cardiac surgery were comparable to those without previous cardiac surgery (P = NS). Stable low thresholds may be chronically maintatined for up to 6 years for epicardial steroid-eluting electrodes irrespective of pacing site or associated cardiac surgery.
引用
收藏
页码:2943 / 2948
页数:6
相关论文
共 26 条
[1]   SUPERIOR VENA-CAVA SYNDROME FOLLOWING PACEMAKER INSERTION POST ATRIAL SEPTAL-DEFECT REPAIR [J].
ANGELI, SJ .
AMERICAN HEART JOURNAL, 1990, 120 (02) :433-435
[2]  
FIGA F, 1995, J AM COLL CARD, pA53
[3]  
FURMAN S, 1993, PRACTICE CARDIAC PAC, P65
[4]   A RANDOMIZED COMPARISON OF A BIPOLAR STEROID-ELUTING ELECTRODE AND A BIPOLAR MICROPOROUS PLATINUM-ELECTRODE - IMPLICATIONS FOR LONG-TERM PROGRAMMING [J].
GILLIS, AM ;
ROTHSCHILD, JM ;
HILLIER, K ;
FUDGE, W ;
KIESER, TM ;
MAITLAND, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (05) :964-970
[5]   STEROID-ELUTING EPICARDIAL LEADS IN PEDIATRICS - IMPROVED EPICARDIAL THRESHOLDS IN THE 1ST YEAR [J].
HAMILTON, R ;
GOW, R ;
BAHORIC, B ;
GRIFFITHS, J ;
FREEDOM, R ;
WILLIAMS, W .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11) :2066-2072
[6]   STEROID-ELUTING EPICARDIAL PACING LEADS IN PEDIATRIC-PATIENTS - ENCOURAGING EARLY RESULTS [J].
JOHNS, JA ;
FISH, FA ;
BURGER, JD ;
HAMMON, JW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) :395-401
[7]   A NEW LOW THRESHOLD PLATINIZED EPICARDIAL PACING ELECTRODE - COMPARATIVE-EVALUATION IN IMMATURE CANINES [J].
KARPAWICH, PP ;
STOKES, KB ;
HELLAND, JR ;
JUSTICE, CD ;
ROSKAMP, JO .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (08) :1139-1148
[8]   IMPROVED CHRONIC EPICARDIAL PACING IN CHILDREN - STEROID CONTRIBUTION TO POROUS PLATINIZED ELECTRODES [J].
KARPAWICH, PP ;
HAKIMI, M ;
ARCINIEGAS, E ;
CAVITT, DL .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (08) :1151-1157
[9]  
KARPAWICH PP, 1989, AM J CARDIOL, V64, P423
[10]  
KARPAWICH PP, 1991, PACEMAKER LEADS 1991, P593