Using Increased Structural Detail of the Cortex to Improve the Accuracy of Modeling the Effects of Transcranial Magnetic Stimulation on Neocortical Activation

被引:22
作者
Chen, Ming [1 ,2 ]
Mogul, David Jeffery [1 ]
机构
[1] IIT, Dept Biomed Engn, Pritzker Inst Biomed Sci & Engn, Chicago, IL 60616 USA
[2] Materialise, Ann Arbor, MI 48103 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Finite-element model; MRI; noninvasive brain stimulation; Transcranial magnetic stimulation (TMS); FINITE-ELEMENT-ANALYSIS; MOTOR CORTEX; SIMULATION;
D O I
10.1109/TBME.2009.2037493
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Transcranial magnetic stimulation (TMS) is a noninvasive technique that can alter brain activation by inducing electrical current in neurons using dynamic magnetic fields. Because of its painless nature, clinical usage has expanded to diagnostic purposes and therapeutic treatments. However, several issues and challenges still exist for TMS. A very limited understanding of the interaction between magnetic fields, cortical structure, and consequent brain excitation is currently available. Most previously published models lack key anatomical details that are essential elements in calculating induced electric fields critical to brain activation. In this study, gross human brain and head structures were derived using multiple modality images and a finite-element model was constructed. Furthermore, microstructural detail was incorporated using neocortical columnar structures. Using this detailed model, we investigated the influence of TMS coil position, distance and orientation on induced electric fields, and neocortical activation. Several activation standards and conductivity values were tested for their impact on the distribution of neocortical activation. Optimized activation patterns agreed well with published clinical experiments, under similar coil configurations. A structurally detailed finite-element model capable of accurately predicting neocortical activation for a given coil/magnetic field profile may provide a critical resource for understanding the electrophysiological consequences of TMS and for further refinement of this important technique.
引用
收藏
页码:1216 / 1226
页数:11
相关论文
共 28 条
[1]  
BARKER AT, 1985, LANCET, V1, P1106
[2]   ON THE USE OF THE MAGNETIC VECTOR POTENTIAL IN THE FINITE-ELEMENT ANALYSIS OF 3-DIMENSIONAL EDDY CURRENTS [J].
BIRO, O ;
PREIS, K .
IEEE TRANSACTIONS ON MAGNETICS, 1989, 25 (04) :3145-3159
[3]   The minicolumn hypothesis in neuroscience [J].
Buxhoeveden, DP ;
Casanova, MF .
BRAIN, 2002, 125 :935-951
[4]   A structurally detailed finite element human head model for simulation of transcranial magnetic stimulation [J].
Chen, Ming ;
Mogul, David Jeffery .
JOURNAL OF NEUROSCIENCE METHODS, 2009, 179 (01) :111-120
[5]   MAGNETIC STIMULATION - DETERMINATION OF COIL CURRENT FLOW DIRECTION [J].
CHIAPPA, KH ;
CROS, D ;
COHEN, D .
NEUROLOGY, 1991, 41 (07) :1154-1155
[6]   ELECTRIC AND MAGNETIC STIMULATION OF HUMAN MOTOR CORTEX - SURFACE EMG AND SINGLE MOTOR UNIT RESPONSES [J].
DAY, BL ;
DRESSLER, D ;
DENOORDHOUT, AM ;
MARSDEN, CD ;
NAKASHIMA, K ;
ROTHWELL, JC ;
THOMPSON, PD .
JOURNAL OF PHYSIOLOGY-LONDON, 1989, 412 :449-473
[7]   ELECTRIC-FIELD INDUCED IN A SPHERICAL VOLUME CONDUCTOR FROM ARBITRARY COILS - APPLICATION TO MAGNETIC STIMULATION AND MEG [J].
EATON, H .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (04) :433-440
[8]  
Fox P.F., 2004, CHEESE CHEM PHYS MIC
[9]   Anisotropy in the visual cortex investigated by neuronavigated transcranial magnetic stimulation [J].
Kammer, Thomas ;
Vorwerg, Michael ;
Herrnberger, Baerbel .
NEUROIMAGE, 2007, 36 (02) :313-321
[10]   Current density threshold for the stimulation of neurons in the motor cortex area [J].
Kowalski, T ;
Silny, J ;
Buchner, H .
BIOELECTROMAGNETICS, 2002, 23 (06) :421-428