Development of an amperometric biosensor based on acetylcholine esterase covalently bound to a new support material

被引:50
作者
Khayyami, M
Pita, MTP
Garcia, NP
Johansson, G
Danielsson, B
Larsson, PO
机构
[1] Univ Lund, Ctr Chem & Chem Engn, Dept Pure & Appl Biochem, S-22100 Lund, Sweden
[2] TMS CHEM AB, S-22370 Lund, Sweden
[3] Univ Lund, Ctr Chem & Chem Engn, Dept Analyt Chem, S-22100 Lund, Sweden
关键词
RVC-electrode; biosensor; acetylcholine esterase; acetylthiocholine; amperometric; thiocholine; mediator; superporous agarose gel;
D O I
10.1016/S0039-9140(97)00182-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new type of amperometric biosensor based on immobilised acetylcholine esterase was designed and constructed. The enzyme was immobilised on a flow-through working electrode, which was prepared from reticulated vitreous carbon (RVC) or from a composite material consisting of RVC and superporous agarose. The sensor was operated in FIA mode using acetylthiocholine as a substrate. The sensor responded to inhibitors such as paraoxon-10(-9) mol was detected by the sensor in a non-optimised configuration. The practical lifetime of the sensor was at least 1 month. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:557 / 563
页数:7
相关论文
共 16 条
[1]   BIOCHEMICAL ASPECTS OF BIOSENSORS [J].
BYFIELD, MP ;
ABUKNESHA, RA .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (4-5) :373-400
[2]   ELECTROCATALYTIC OXIDATION OF REDUCED NICOTINAMIDE COENZYMES BY GRAPHITE-ELECTRODES MODIFIED WITH AN ADSORBED PHENOXAZINIUM SALT, MELDOLA BLUE [J].
GORTON, L ;
TORSTENSSON, A ;
JAEGFELDT, H ;
JOHANSSON, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 161 (01) :103-120
[3]   Superporous agarose, a new material for chromatography [J].
Gustavsson, PE ;
Larsson, PO .
JOURNAL OF CHROMATOGRAPHY A, 1996, 734 (02) :231-240
[4]   ELECTROCATALYTIC AND ANALYTICAL RESPONSE OF COBALT PHTHALOCYANINE CONTAINING CARBON PASTE ELECTRODES TOWARD SULFHYDRYL COMPOUNDS [J].
HALBERT, MK ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1985, 57 (03) :591-595
[5]   Flow-injection determination of trace hydrogen peroxide or glucose utilizing an amperometric biosensor based on glucose oxidase bound to a reticulated vitreous carbon electrode [J].
Khayyami, M ;
Johansson, G ;
Kriz, D ;
Xie, B ;
Larsson, PO ;
Danielsson, B .
TALANTA, 1996, 43 (06) :957-962
[6]   An amperometric lactate sensor based on a NAD(+)-analog and lactate dehydrogenase coimmobilized on reticulated vitreous carbon [J].
Khayyami, M ;
Garcia, NP ;
Larsson, PO ;
Danielsson, B ;
Johansson, G .
ELECTROANALYSIS, 1997, 9 (07) :523-526
[7]   PRINTED AMPEROMETRIC SENSOR BASED ON TCNQ AND CHOLINESTERASE [J].
KULYS, J ;
DCOSTA, EJ .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (02) :109-115
[8]  
LARSSON PO, Patent No. 92008275
[9]   A COMPARATIVE-STUDY OF SOME 3,7-DIAMINOPHENOXAZINE DERIVATIVES AND RELATED-COMPOUNDS FOR ELECTROCATALYTIC OXIDATION OF NADH [J].
PERSSON, B ;
GORTON, L .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 292 (1-2) :115-138
[10]  
Porath J, 1976, Methods Enzymol, V44, P19