A simplified approach to capillary electrophoretic separation of polymerase chain reaction fragments of forensic interest

被引:2
作者
Manetto, G [1 ]
Crivellente, F [1 ]
Tagliaro, F [1 ]
Turrina, S [1 ]
Pascali, VL [1 ]
机构
[1] Univ Verona Policlin, Inst Forens Med, I-37134 Verona, Italy
关键词
capillary electrophoresis; LIF; PCR; STRs; CD4;
D O I
10.1016/S0379-0738(98)00022-X
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
We report a sensitive and low-cost capillary electrophoretic typing method and its application to a short tandem repeat system widely used in forensic identification (HUMCD4). Separations are carried out with internally coated 100 mu m fused-silica capillaries filled with a noncrosslinked gel sieving matrix based on 1.50-1.75 hydroxyethylcellulose. Detection was by laser-induced fluorescence detection. As running buffer, 100 mM Tris-borate with 0.1 mM EDTA, pH 8.7, was used. Samples were simply diluted (greater than or equal to 1:10 in water) prior to separation. Both electrokinetic injection and analytical separation were carried our at -180 V/cm. The method enabled separation of HUMCD4 alleles, with fair precision in terms of absolute and relative migration times (R.S.D.s of 0.22% and 0.04%, respectively, in intraday tests). The average accuracy of CD4 fragment sizing was 0.218 base pairs. These results confirmed the high suitability of capillary electrophoresis as a screening method for small-size DNA polymorphisms. (C) 1998 Elsevier Science Ireland Ltd.
引用
收藏
页码:259 / 268
页数:10
相关论文
共 6 条
[1]   APPLICATION OF DUAL INTERNAL STANDARDS FOR PRECISE SIZING OF POLYMERASE CHAIN-REACTION PRODUCTS USING CAPILLARY ELECTROPHORESIS [J].
BUTLER, JM ;
MCCORD, BR ;
JUNG, JM ;
LEE, JA ;
BUDOWLE, B ;
ALLEN, RO .
ELECTROPHORESIS, 1995, 16 (06) :974-980
[2]   CAPILLARY ELECTROPHORESIS OF POLYMERASE CHAIN REACTION-AMPLIFIED DNA USING FLUORESCENCE DETECTION WITH AN INTERCALATING DYE [J].
MCCORD, BR ;
MCCLURE, DL ;
JUNG, JM .
JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (01) :75-82
[3]   HIGH-RESOLUTION CAPILLARY ELECTROPHORESIS OF FORENSIC DNA USING A NON-GEL SIEVING BUFFER [J].
MCCORD, BR ;
JUNG, JM ;
HOLLERAN, EA .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (9-10) :1963-1981
[4]  
RIGHETTI PG, 1996, CRC SER ANAL BIOTECH, P431
[5]   ELECTROPHORETIC SEPARATIONS OF POLYMERASE CHAIN REACTION-AMPLIFIED DNA FRAGMENTS IN DNA TYPING USING A CAPILLARY ELECTROPHORESIS LASER-INDUCED FLUORESCENCE SYSTEM [J].
SRINIVASAN, K ;
GIRARD, JE ;
WILLIAMS, P ;
ROBY, RK ;
WEEDN, VW ;
MORRIS, SC ;
KLINE, MC ;
REEDER, DJ .
JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (01) :83-91
[6]   Short tandem repeat typing by capillary array electrophoresis: Comparison of sizing accuracy and precision using different buffer systems [J].
Vainer, M ;
Enad, S ;
Dolnik, V ;
Xu, D ;
Bashkin, J ;
Marsh, M ;
Tu, O ;
Harris, DW ;
Barker, DL ;
Mansfield, ES .
GENOMICS, 1997, 41 (01) :1-9