Fast separations on monolithic silica columns: method transfer, robustness and column ageing for some case studies

被引:51
作者
van Nederkassel, AM [1 ]
Aerts, A [1 ]
Dierick, A [1 ]
Massart, DL [1 ]
Vander Heyden, Y [1 ]
机构
[1] Free Univ Brussels, Inst Pharmaceut, ChemoAC, B-1090 Brussels, Belgium
关键词
method development; method transfer; monolithic columns; fast analysis; robustness of separation; column ageing;
D O I
10.1016/S0731-7085(03)00131-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Six separation methods, developed on conventional silica high performance liquid chromatography (HPLC) columns were transferred to monolithic silica columns of 5 and 10 cm length. The transferred methods include the separation of an alkylbenzene mixture, the separations of drugs from their impurities (nimesulide, tetracycline, phenoxymethylpenicillin and erythromycin) and the separation of a green tea extract. The transfer of the first three methods was successful while for the latter three it was not. Increasing the flow rate up to 9 ml/min (where possible) inversely decreased the analysis time of the successfully transferred methods to 48 s (alkylbenzene mixture) 1.8 min (nimesulide mixture) and 3 min (tetracycline mixture) while still reasonable well separated peaks were obtained. The robustness and repeatability of the transferred and accelerated separations was found to be acceptable. Despite the use of flow rates up to 9 ml/min and frequent mobile phase changes with pH values varying from 3.5 to 7, the column performance was found to be rather constant and the column ageing to be minimal. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:233 / 249
页数:17
相关论文
共 19 条
[1]   Comparative study on the column performance of microparticulate 5-μm C18-bonded and monolithic C18-bonded reversed-phase columns in high-performance liquid chromatography [J].
Bidlingmaier, B ;
Unger, KK ;
von Doehren, N .
JOURNAL OF CHROMATOGRAPHY A, 1999, 832 (1-2) :11-16
[2]   STATIONARY-PHASE DEGRADATION IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY - A POSSIBLE CAUSE OF BAD PREDICTIONS IN EXPERIMENTAL-DESIGN [J].
BOURGUIGNON, B ;
MASSART, DL .
ANALYTICA CHIMICA ACTA, 1993, 282 (01) :33-45
[3]   INTERLABORATORY VARIABILITY IN TRACE-ELEMENT ANALYSIS [J].
BOYER, KW ;
HORWITZ, W ;
ALBERT, R .
ANALYTICAL CHEMISTRY, 1985, 57 (02) :454-459
[4]  
Cabrera K, 2000, HRC-J HIGH RES CHROM, V23, P93
[5]   Separation of erythromycin and related substances on base-deactivated reversed-phase silica gel columns [J].
Chepkwony, HK ;
Vanderriest, I ;
Nguyo, JM ;
Roets, E ;
Hoogmartens, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 870 (1-2) :227-235
[6]  
Chepkwony HK, 2001, CHROMATOGRAPHIA, V53, P159
[7]   Selection of column and gradient elution system for the separation of catechins in green tea using high-performance liquid chromatography [J].
Dalluge, JJ ;
Nelson, BC ;
Thomas, JB ;
Sander, LC .
JOURNAL OF CHROMATOGRAPHY A, 1998, 793 (02) :265-274
[8]  
DONG F, 1993, STAT SINICA, V3, P209
[9]  
Euerby MR, 2000, LC GC EUR, V13, P665
[10]   Minimal number of chromatographic test parameters for the characterisation of reversed-phase liquid chromatographic stationary phases [J].
Iványi, T ;
Heyden, YV ;
Visky, D ;
Baten, P ;
De Beer, J ;
Lázár, I ;
Massart, DL ;
Roets, E ;
Hoogmartens, J .
JOURNAL OF CHROMATOGRAPHY A, 2002, 954 (1-2) :99-114