Automated 96-well solid phase extraction and hydrophilic interaction liquid chromatography-tandem mass spectrometric method for the analysis of cetirizine (ZYRTEC®) in human plasma -: with emphasis on method ruggedness

被引:47
作者
Qi, S
Junga, H
Yong, T
Li, AC
Addison, T
McCort-Tipton, M
Beato, B
Weng, ND
机构
[1] Covance Bioanalyt Serv, Indianapolis, IN 46214 USA
[2] Covance Bioanalyt Chem, Madison, WI USA
[3] Covance Drug Metab, Madison, WI USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2005年 / 814卷 / 01期
关键词
cetirizine; synthesis of cetirizine-d(8); HILIC-MS/MS; method validation;
D O I
10.1016/j.jchromb.2004.10.009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-throughput bioanalytical method based on automated sample transfer, automated solid phase extraction, and hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) analysis. has been developed for the determination of cetirilzine, a selective H-1-receptor antagonist. Deuterated cetirizine (cetirizine-d(8)) was synthesized as described and was used a, the internal standard. Samples were transferred into 96-well plates using an automated sample handling system. Automated solid phase extraction was carried out using a 96-channel programmable liquid-handling workstation. Solid phase extraction 96-well plate on polymer sorbent (Strata X) was used to extract the analyte. The extracted samples were injected onto a Betasil silica column (50 x 3.5 mum) using a mobile phase of acetonitrile-water-acetic acid-trifluroacetic acid (93:7:1:0.025, v/v/v/v) at a flow rate of 0.5 ml/min. The chromatographic run time is 2.0 min per injection, with retention time of cetirizine and cetirizine-d(8) both at 1.1 min. The system consisted of a Shimadzu HPLC system and a PE Sciex API 3000 or API 4000 tandem mass spectrometer with (+) ESI. The method has been validated over the concentration range of 1.00-1000 ng/ml cetirizine inhuman plasma, based on a 0.10-ml sample size. The inter-day precision and accuracy of the quality control (QC) samples demonstrated <3.0% relative standard deviation (R.S.D.) and <6.0% relative error (RE). Stability of cetirizine in stock solution. in plasma, and in reconstitution solution was established. The absolute extraction recovery was 85.8%, 84.5%, and 88.0%, at 3, 40, and 800 ng/ml. respectively. The recovery for the internal standard was 84.1%. No adverse matrix effects were noticed for this assay. The automation of the sample preparation steps not only increased the analysis throughput, but also increased method ruggedness. The use of a stable isotope-labeled internal standard further improved the method ruggedness. Practical issues of analyzing incurred samples were discussed. This HILIC-MS/MS method for analysis of citirizine in human plasma was successfully used to support clinical studies. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:105 / 114
页数:10
相关论文
共 44 条
[1]  
Allanson JP, 1996, RAPID COMMUN MASS SP, V10, P811, DOI 10.1002/(SICI)1097-0231(199605)10:7<811::AID-RCM561>3.0.CO
[2]  
2-Q
[3]   GAS-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF CETIRIZINE IN PLASMA [J].
BALTES, E ;
COUPEZ, R ;
BROUWERS, L ;
GOBERT, J .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 430 (01) :149-155
[4]   Hydrophilic interaction liquid chromatography/electrospray mass spectrometry determination of acyclovir in pregnant rat plasma and tissues [J].
Brown, SD ;
White, CA ;
Bartlett, MG .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (19) :1871-1876
[5]   CETIRIZINE - A REVIEW OF ITS PHARMACOLOGICAL PROPERTIES AND CLINICAL POTENTIAL IN ALLERGIC RHINITIS, POLLEN-INDUCED ASTHMA, AND CHRONIC URTICARIA [J].
CAMPOLIRICHARDS, DM ;
BUCKLEY, MMT ;
FITTON, A .
DRUGS, 1990, 40 (05) :762-781
[6]   Stereoselective determination of cetirizine and studies on pharmacokinetics in rat plasma [J].
Choi, SO ;
Lee, SH ;
Kong, HS ;
Kim, EJ ;
Choo, HYP .
JOURNAL OF CHROMATOGRAPHY B, 2000, 744 (01) :201-206
[7]  
*COMP INC, 2000, PHYS DESK REF 54 MED, P2404
[8]   High-performance liquid chromatographic-tandem mass spectrometric method for the determination of ethionamide in human plasma, bronchoalveolar lavage fluid and alveolar cells [J].
Conte, JE ;
Wang, GF ;
Lin, ET ;
Zurlinden, E .
JOURNAL OF CHROMATOGRAPHY B, 2001, 753 (02) :343-353
[9]   Extractionless and sensitive method for high-throughput quantitation of cetirizine in human plasma samples by liquid chromatography-tandem mass spectrometry [J].
de Jager, AD ;
Hundt, HKL ;
Swart, KJ ;
Hundt, AF ;
Els, J .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (02) :113-118
[10]   Determination of cetirizine in human plasma by liquid chromatography-tandem mass spectrometry [J].
Eriksen, H ;
Houghton, R ;
Green, R ;
Scarth, J .
CHROMATOGRAPHIA, 2002, 55 (Suppl 1) :S145-S149