Temperature effects on separation on zirconia columns: Applications to one- and two-dimensional LC separations of phenolic antioxidants

被引:35
作者
Cacciola, Francesco
Jandera, Pavel
Mondello, Luigi
机构
[1] Univ Pardubice, Dept Analyt Chem, Pardubice 53210, Czech Republic
[2] Univ Messina, Dipartimento Farmacochim, Messina, Italy
关键词
comprehensive LC x LC chromatography; high-temperature LC; natural antioxidants; phenolic compounds; zirconia-carbon column;
D O I
10.1002/jssc.200600387
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The effects of temperature and mobile phase on LC chromatographic separation of phenolic antioxidants on zirconia-based columns were investigated. Unlike silica-based materials, zirconia columns show excellent thermal stability over a wide range of temperatures and enable high-temperature separations. Enthalpic and entropic contributions to the retention of phenolic compounds on ZR-Carbon and ZR-Carbon C18 columns were determined from retention versus temperature plots in order to elucidate the retention mechanism of sample compounds over the temperature range up to 140 degrees C. High-temperature liquid chromatography on ZR-Carbon columns was used for comprehensive LC x LC two-dimensional separation systems based on the different selectivity of a Zorbax SB micro-column used in the first dimension and a ZR-Carbon column used in the second dimension. Two-dimensional LC x LC systems employing a setup with two alternately operated parallel ZR-Carbon columns in the second dimension were used for the analysis of phenolic antioxidants in beer and wine samples.
引用
收藏
页码:462 / 474
页数:13
相关论文
共 49 条
[1]   Determination of phenolic acids in fruit juices by isocratic column liquid chromatography [J].
Amakura, Y ;
Okada, M ;
Tsuji, S ;
Tonogai, Y .
JOURNAL OF CHROMATOGRAPHY A, 2000, 891 (01) :183-188
[2]   The temperature convergence of biopolymers in reversed-phase liquid chromatography [J].
Bai, Q ;
Geng, XD .
CHROMATOGRAPHIA, 2001, 54 (5-6) :335-338
[3]   Two-dimensional and serial column reversed-phase separation of phenolic antioxidants on octadecyl-, polyethyleneglycol-, and pentafluorophenylpropyl-silica columns [J].
Blahová, E ;
Jandera, P ;
Cacciola, F ;
Mondello, L .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (04) :555-566
[4]   TEMPERATURE PROGRAMMED MICROBORE HPLC .1. [J].
BOWERMASTER, J ;
MCNAIR, HM .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1984, 22 (04) :165-170
[5]   MICROBORE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMNS - SPEED, EFFICIENCY, SENSITIVITY AND TEMPERATURE PROGRAMMING [J].
BOWERMASTER, J ;
MCNAIR, H .
JOURNAL OF CHROMATOGRAPHY, 1983, 279 (NOV) :431-438
[6]   Development of different comprehensive two dimensional systems for the separation of phenolic antioxidants [J].
Cacciola, Francesco ;
Jandera, Pavel ;
Blahova, Eva ;
Mondello, Luigi .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (16) :2500-2513
[7]   Separation and determination of flavonoids and other phenolic compounds in cranberry juice by high-performance liquid chromatography [J].
Chen, H ;
Zuo, YG ;
Deng, YW .
JOURNAL OF CHROMATOGRAPHY A, 2001, 913 (1-2) :387-395
[8]  
Chen MH, 1997, J CHROMATOGR A, V788, P51
[9]   Comparison of the chromatography of octadecyl silane bonded silica and polybutadiene-coated zirconia phases based on a diverse set of cationic drugs [J].
Dai, J ;
Yang, XQ ;
Carr, PW .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1005 (1-2) :63-82
[10]   Selection of column and gradient elution system for the separation of catechins in green tea using high-performance liquid chromatography [J].
Dalluge, JJ ;
Nelson, BC ;
Thomas, JB ;
Sander, LC .
JOURNAL OF CHROMATOGRAPHY A, 1998, 793 (02) :265-274